A pulse forming module (PFM) with a multifunction of energy storage and a quasi-squared pulse output is developed to meet the challenge of a compact design and square output waveform in a high-power Marx generator. A simplified pulse forming circuit comprising only 2 parallel connected sections, in which every section contains an inductor and a capacitor in series, has been proposed and investigated carefully to obtain a quasi-squared waveform. Influences of inductance values in the circuit on its output waveform to a resistive load are investigated. PFMs are designed and fabricated based on the 2 section circuit, in which series folded film capacitors are employed to achieve a high energy density of 0.04 J/cm at a charging voltage of 120 kV. The as-designed module can output a quasi-squared waveform with FWHM of about 180 ns and the flattop duration greater than 90 ns. It can work at a repetition rate as high as 50 Hz, while the output waveforms show small differences. This research has developed a PFM with a quasi-squared output waveform based on a simplified 2 section circuit, which shows potential to reduce the size of the high power generator system that is based on it.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.5030568 | DOI Listing |
Sci Rep
January 2025
Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.
Roaming reactions involving a neutral fragment of a molecule that transiently wanders around another fragment before forming a new bond are intriguing and peculiar pathways for molecular rearrangement. Such reactions can occur for example upon double ionization of small organic molecules, and have recently sparked much scientific interest. We have studied the dynamics of the [Formula: see text]-roaming reaction leading to the formation of [Formula: see text] after two-photon double ionization of ethanol and 2-aminoethanol, using an XUV-UV pump-probe scheme.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
The importance of continuous and reliable pulse wave monitoring is constantly being increased in health signal monitoring and disease diagnoses. Flexible pressure sensors with high sensitivity, low hysteresis and fast response time are an effective means for monitoring pulses. Herein, a special wave-shaped layered porous structure of carbonized wood cellulose sponge (CWCS) was constructed based on natural wood (NW).
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
School of Health Sciences, Stopford Building, The University of Manchester, Oxford Road, Manchester M13 9PT, UK.
Mikrochim Acta
January 2025
College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, 26 Yuxiang Road, Shijiazhuang, 050018, P. R. China.
An aptamer-antibody sandwich electrochemical immunosensor was studied. FeO/MWCNTs-COOH/Nafion was modified and fixed on a glassy carbon electrode to amplify electrical signals. The antibody was coupled with AuNPs to form conjugates.
View Article and Find Full Text PDFToxins (Basel)
January 2025
Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague, Technicka 3, 166 28 Prague, Czech Republic.
fungi are widespread pathogens of food crops, primarily associated with the formation of mycotoxins. Therefore, effective mitigation strategies for these toxicogenic microorganisms are required. In this study, the potential of pulsed electric field (PEF) as an advanced technology of increasing use in the food processing industry was investigated to minimize the viability of pathogens and to characterize the PEF-induced changes at the metabolomic level.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!