A Cherenkov neutron time-of-flight (nTOF) detector developed and constructed at Lawrence Livermore National Laboratory was tested at 13 m from the target in a collimated line of sight (LOS) and at 5.3 m from the target in the open space inside the OMEGA Target Bay. Neutrons interacting with the quartz rod generate gammas, which through Compton scattering produce relativistic electrons that give rise to Cherenkov light. A photomultiplier tube (PMT) transferred the Cherenkov light into an amplified electrical signal. The Cherenkov nTOF detector consists of an 8-mm-diam, 25-cm quartz hexagonal prism coupled with a Hamamatsu gated PMT R5916U-52. The tests were performed with DT direct-drive implosions with cryogenic and room-temperature targets, producing a wide range of neutron yields and ion temperatures. The results of the tests and comparison with other nTOF detectors on OMEGA are presented. In the collimated LOS at 13 m from the target, the Cherenkov nTOF detector demonstrated good precision measurement in both the yield and ion temperature for DT yields above 3 × 10.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.5035289 | DOI Listing |
Rev Sci Instrum
December 2024
Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
As neutron yields increase at fusion facilities, a universal symptom the community must deal with is MeV neutron-induced backgrounds in cables running to diagnostics. On the first Gain >1 plasmas in the world, the National Ignition Facility (NIF) neutron time-of-flight (nToF) diagnostic registered significant cable backgrounds that compromised key performance measurements. The South Pole nToF is uniquely located inside the NIF Target Bay shield walls, ∼18 m from the fusion source, and consequently has long coaxial cable runs (>20 m) that see significant neutron fluence.
View Article and Find Full Text PDFRev Sci Instrum
October 2024
Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299, USA.
Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator's light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed.
View Article and Find Full Text PDFRev Sci Instrum
September 2024
Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium-tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al.
View Article and Find Full Text PDFRev Sci Instrum
August 2024
Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
On pulsed fusion experiments, the neutron time of flight (nToF) diagnostic provides critical information on the fusion neutron energy spectrum. This work presents an analysis technique that uses two collinear nToF detectors, potentially to measure nuclear bang time and directional flow velocities. Two collinear detectors may be sufficient to disambiguate the contributions of nuclear bang time and directional flow velocities to the first moment of the neutron energy spectrum, providing an independent measurement of nuclear bang time.
View Article and Find Full Text PDFRev Sci Instrum
August 2024
Sandia National Laboratories, 1515 Eubank SE, Albuquerque, New Mexico 87185, USA.
The neutron time-of-flight (nToF) diagnostic technique has a lengthy history in Inertial Confinement Fusion (ICF) and High Energy Density (HED) Science experiments. Its initial utility resulted from the simple relationship between the full width half maximum of the fusion peak signal in a distant detector and the burn averaged conditions of an ideal plasma producing the flux [Lehner and Pohl, Z. Phys.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!