The neutron camera upgrade for MAST Upgrade.

Rev Sci Instrum

Department of Physics and Astronomy, Uppsala University, EURATOM-VR Association, Uppsala, Sweden.

Published: October 2018

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard -rays sources and a Cf source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. The energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5038948DOI Listing

Publication Analysis

Top Keywords

mast upgrade
12
neutron camera
8
camera upgrade
8
upgrade ncu
8
spatial resolution
8
neutron
6
upgrade
5
upgrade mast
4
upgrade neutron
4
ncu neutron
4

Similar Publications

Background And Objective: Prostate cancer (PC) heterogeneity can result in sampling discrepancies during biopsy, leading to inaccurate molecular classifications that affect treatment decisions. We evaluated transcriptomic profile variability between multiparametric magnetic resonance imaging (mpMRI)-targeted biopsy (TBx) and systematic biopsy (SBx) methods using the Decipher GRID platform.

Methods: The study included 205 men from the MAST trial.

View Article and Find Full Text PDF

Understanding the confinement of fast ions is crucial for plasma heating and non-inductive current drive, i.e., for the operation of a fusion reactor.

View Article and Find Full Text PDF

The infrared thermography system on the MAST-U tokamak.

Rev Sci Instrum

November 2024

United Kingdom Atomic Energy Authority, Culham Campus, Abingdon, Oxon OX14 3DB, United Kingdom.

Power loading from plasma in the scrape-off layer limits the lifetime of plasma-facing components in tokamak-based power plants. The Mega Ampere Spherical Tokamak Upgrade [W. Morris et al.

View Article and Find Full Text PDF

Validated and accurate edge profiles (temperature, density, etc.) are vitally important to the Mega Ampere Spherical Tokamak Upgrade (MAST-U) divertor and confinement effort. Density profile reflectometry has the potential to significantly add to the measurement capabilities currently available on MAST-U (e.

View Article and Find Full Text PDF

First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U).

Rev Sci Instrum

August 2024

United Kingdom Atomic Energy Authority, Culham Campus, Abingdon OX14 3DB, United Kingdom.

First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!