A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Massive Hemorrhage From Suspected Iatrogenic Uterine Rupture. | LitMetric

Massive Hemorrhage From Suspected Iatrogenic Uterine Rupture.

Obstet Gynecol

Division of Obstetrical Anesthesiology, Department of Anesthesiology, and the Division of Obstetrics and Gynecology, Northwestern University Feinberg School of Medicine, Chicago, Illinois; and the Division of Obstetrical Anesthesiology, Department of Anesthesiology, Vanderbilt University Medical Center, Nashville, Tennessee.

Published: December 2018

Background: Intrauterine balloon tamponade is recommended for refractory postpartum hemorrhage resulting from atony, but few studies have assessed complications associated with placement.

Case: A 39-year-old woman, gravida 4 para 1, with posterior placenta previa and suspected placenta accreta had a postpartum hemorrhage after a scheduled cesarean delivery. An intrauterine balloon tamponade device was easily placed transcervically; however, the patient required additional analgesia for constant severe stabbing pain worsened on examination. Three hours after placement, the balloon was expelled from the cervix, resulting in 1,500 mL of fresh blood and clot. Emergent exploratory laparotomy identified a uterine rupture inferior and lateral to the hysterotomy site.

Conclusion: Intrauterine balloon tamponade may contribute to iatrogenic uterine rupture and should be considered in patients with refractory hemorrhage, hemodynamic instability, or severe pain despite analgesia.

Download full-text PDF

Source
http://dx.doi.org/10.1097/AOG.0000000000002971DOI Listing

Publication Analysis

Top Keywords

uterine rupture
12
intrauterine balloon
12
balloon tamponade
12
iatrogenic uterine
8
postpartum hemorrhage
8
massive hemorrhage
4
hemorrhage suspected
4
suspected iatrogenic
4
rupture background
4
background intrauterine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!