A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of Absorb bioresorbable scaffold implantation technique on post-procedural quantitative coronary angiographic endpoints in ST-elevation myocardial infarction: a sub-analysis of the BVS STEMI STRATEGY-IT study. | LitMetric

Aims: The aim of the study was to evaluate the impact of bioresorbable vascular scaffold (BRS) implantation technique on post-procedural quantitative coronary angiography (QCA) parameters in ST-elevation myocardial infarction (STEMI).

Methods And Results: We assessed 442 STEMI patients who underwent BRS implantation in the BVS STEMI STRATEGY-IT study. Optimal BRS implantation was assessed using the PSP score, developed and validated in the GHOST-EU registry. We analysed post-implantation QCA parameters, including minimum lumen diameter (MLD) and maximum footprint, in patients with and without optimal BRS implantation, coded as maximum PSP score. Patients with optimal BRS implantation had higher post-procedural MLD and lower maximum footprint than those without. Multivariate analysis demonstrated that optimal BRS implantation was an independent predictor of high post-procedural MLD, defined as ≥2.4 mm for 2.5 or 3.0 mm BRS and ≥2.8 mm for 3.5 mm BRS. Thrombectomy before optimal BRS implantation showed a trend towards higher post-procedural MLD and lower maximum footprint. There was no relationship between optimal BRS implantation and device-oriented composite events at one year.

Conclusions: Optimal BRS implantation, as assessed by PSP score, was associated with better post-procedural QCA parameters in STEMI. Thrombectomy before optimal BRS implantation might improve angiographic results in STEMI. Long-term follow-up is needed to analyse the relationship between QCA parameters and clinical outcomes after BRS implantation in STEMI patients.

Download full-text PDF

Source
http://dx.doi.org/10.4244/EIJ-D-18-00504DOI Listing

Publication Analysis

Top Keywords

brs implantation
44
optimal brs
32
qca parameters
16
brs
13
implantation
12
psp score
12
maximum footprint
12
post-procedural mld
12
implantation technique
8
technique post-procedural
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!