Purpose: To measure contact forces (CFs) at standardized locations representative of clinical articular cartilage defects on the medial and lateral femoral condyles during robotic tests with simulated weightbearing knee flexion.
Methods: Eleven human knees had 20-mm-diameter cylinders of native bone/cartilage cored from both femoral condyles at standardized locations, with each cylinder attached to a custom-built load cell that maintained the plug in its precise anatomic position. A robotic test system was used to flex the knee from 0° to 50° under 200-N tibiofemoral compression without and with a 2 Nm internal tibial torque, 5 Nm external tibial torque, and 45 N anterior tibial force (AF). CFs and knee kinematics were recorded before and after cutting the anterior cruciate ligament (ACL).
Results: ACL sectioning did not significantly increase medial or lateral CFs for any loading condition, with the exception of AF, in which increases in medial CF ranged from 38 N (at 15° flexion, P < .01) to 77 N (at 50° flexion, P < .002). Compared with the intact condition, ACL sectioning significantly increased anterior tibial translation by 12.33 mm (at 15° flexion, P < .001) and 17.4 mm (at 50° flexion, P < .001), and increased valgus rotation by 2.4° (at 15° flexion, P < .001) and 3.8° (at 50° flexion, P < .001).
Conclusions: Our hypothesis that CF would increase after ACL section was confirmed for the AF test condition only, and only for the medial condyle beyond 10° flexion. With the ACL sectioned, it appeared that the increased CF was owing to the medial condyle riding up over the posterior tibial plateau resulting from the large anterior tibial displacements.
Clinical Relevance: Aside from our limited finding with AF, we concluded that CFs were generally unaffected by ACL section.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arthro.2018.06.051 | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Applied Mathematics Laboratory, Courant Institute of Mathematical Sciences, Department of Mathematics, New York University, New York, NY 10012.
Mechanical systems with moving points of contact-including rolling, sliding, and impacts-are common in engineering applications and everyday experiences. The challenges in analyzing such systems are compounded when an object dynamically explores the complex surface shape of a moving structure, as arises in familiar but poorly understood contexts such as hula hooping. We study this activity as a unique form of mechanical levitation against gravity and identify the conditions required for the stable suspension of an object rolling around a gyrating body.
View Article and Find Full Text PDFJ Craniofac Surg
January 2025
Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China.
Objective: Finite element analysis (FEA) of the biomechanical properties of the modified extraoral distractor device used in the mandibular distraction of craniofacial microsomia patients.
Materials And Methods: Finite element analysis (FEA) models of 5 patients under 2 working conditions, the instance when the distractor is activated and when the distractor participates in mastication, were included in the current study. To conduct the FEA, load boundary conditions (35.
J Contemp Dent Pract
September 2024
Department of Preventive and Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.
Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.
Materials And Methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency.
J Biomech Eng
January 2025
Human-Centric Design Research Lab, Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
This study presents a comprehensive finite element model for the human wrist, constructed from a CT scan of a 68-year-old male (type I wrist). This model intricately captures the bone and soft tissue geometries to study the biomechanics of wrist axial loading through tendon-driven simulations and grasping biomechanics using metacarpal loads. Validation is carried out by assessing the radial and ulnar axial loading distribution, radiocarpal articulation contact patterns, and other standard finite element metrics.
View Article and Find Full Text PDFSoft Matter
January 2025
Delft University of Technology, Process & Energy Laboratory, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands.
The jamming transition of soft particles characterized by narrow size distributions has been well studied by physicists. However, polydispersed systems are more relevant to engineering, and the influence of polydispersity on jamming phenomena is still unexplored. Here, we numerically investigate jamming transitions of polydispersed soft particles in two dimensions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!