Background: In the past, manufacture of prosthetic socket by using traditional handmade method not only consumed research time but also required a special assembly approach. Recently, reverse engineering and rapid prototype technology have grown up explosively, and thus, provide a choice to fabricate prosthetic socket.
Methods: Application 3D computer aided design and manufacturing (computer-aided design/computer-aided engineering) tools approach the surface shape stump data is digitized and can be easily modified and reused. Collocation investigates gait parameters of prosthetic socket, and interface stress between stump and socket with different processing conditions. Meanwhile, questionnaire was utilized to survey satisfaction rating scale, comfort level, of subjects using this kind of artificial device.
Results: The main outcome of current research including gait parameters, stress interface and satisfaction rating scale those would be an informative reference for further studies in design and manufacture as well as clinical applications of prosthetic sockets.
Conclusions: This study found that, regardless of the method used for socket fabrication, most stress was concentrated in tibia end pressure-relief area. This caused discomfort in the area of tibia end to the participant wearing prosthesis. This discomfort was most evident in case when the prosthetic socket was fabricated using RE and RP.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6219010 | PMC |
http://dx.doi.org/10.1186/s12938-018-0577-2 | DOI Listing |
Prosthet Orthot Int
January 2025
Green Pastures Hospital and Rehabilitation Centre, Pokhara, Nepal.
Introduction: Prosthetic silicone liners improve comfort and skin protection and allow the use of total surface bearing (TSB) sockets, which provide enhanced proprioception and comfort. Unfortunately, silicone liners are cost-prohibitive in resource-limited environments (RLEs) where patellar tendon bearing (PTB) sockets with PE-lite liners remain standard, leading to patient discomfort and skin issues.
Objective: This study evaluates the benefits and durability of an affordable silicone liner locally manufactured in an RLE to promote TSB socket adoption, aiming to enhance prosthetic care and patient outcomes.
BMC Oral Health
January 2025
Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt.
Background: Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard to seal without reflecting the mucoperiosteal flap, extraction sockets anatomy that are not suitable for regular healing abutment placement, and potentially high occlusal stresses when planning a temporary implant supported prothesis to improve the conditioning of supra implant tissue architecture and the emergence profile of the implant supported restorations.
Purpose: To clinically evaluate the peri-implant soft tissue profile of single posterior implant retained restorations and to assess patient related outcomes of the implant restorations that were conditioned immediately by CAD-CAM socket sealing abutments (SSA) versus those conditioned by Titanium (Ti) standard healing abutments (SHA).
Methods: Twenty participants received twenty-two single maxillary immediate implants after flapless minimally invasive tooth extraction and 3D guided implant placement in the posterior area (premolar and molar) and allocated randomly into two groups (n = 11), the intervention group: patients received PEEK SSA and the control group: the patients received Ti SHA.
Arch Orthop Trauma Surg
January 2025
BG Klinikum Unfallkrankenhaus Berlin, Department of Hand-, Replantation- and Microsurgery and Chair of Hand-, Replantation- and Microsurgery, Charité Universitätsmedizin Berlin, Berlin, Germany.
Introduction: Rhizarthrosis, or osteoarthritis of the trapeziometacarpal joint, predominantly affects women over 50, with up to 30% experiencing some degree of arthritis in this joint. Traditional surgical approaches, such as trapeziectomy with ligament reconstruction, can result in some patients in persistent pain or limited functionality. TMC ball-in-socket arthroplasty, with a cup placed in the distal scaphoid, offers a promising alternative to traditional arthrodesis or resection-suspension arthroplasty.
View Article and Find Full Text PDFJ Clin Med
December 2024
Dentistry and Maxillo-Facial Surgery Unit, Department of Surgery, Dentistry, Paediatrics and Gynaecology (DIPSCOMI), University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy.
The aim of this retrospective study was to compare the histomorphometry of post-extractive sites previously grafted with deproteinized bovine bone, with or without the association of a calcium sulphate preparation. The retrospective evaluation comprehended patients previously selected and treated for the extraction of one or more mono-radicular teeth, followed by an implant-prosthetic rehabilitation. Post-extractive sites had been randomly assigned to test or control group, respectively, if deproteinized bovine bone was used in association with a calcium sulphate preparation or alone.
View Article and Find Full Text PDFJ Biomech
January 2025
Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, 151 boulevard de l'Hôpital, 75013 Paris, France. Electronic address:
Improper socket fitting in lower-limb prostheses can lead to significant complications, including pain, skin lesions, and pressure ulcers. Current suspension and socket design practices rely predominantly on visual inspection of the residual limb and patient feedback. Monitoring stress distribution at the residual limb/socket interface offers a more objective approach.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!