Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Statins, HMG-CoA reductase inhibitors, are considered the first line treatment of hyperlipidemia to reduce the risk of atherosclerotic cardiovascular diseases. The prevalence of hyperlipidemia and the risk of atherosclerotic cardiovascular diseases are higher in obese patients. Published methods for the quantification of statins and their active metabolites did not test for matrix effect of or validate the method in hyperlipidemic plasma. A sensitive, specific, accurate, and reliable LC-MS/MS method for the simultaneous quantification of simvastatin (SMV), active metabolite of simvastatin acid (SMV-A), atorvastatin (ATV), active metabolites of 2-hydroxy atorvastatin (2-OH-ATV), 4-hydroxy atorvastatin (4-OH-ATV), and rosuvastatin (RSV) was developed and validated in plasma with low (52-103 mg/dl, <300 mg/dl) and high (352-403 mg/dl, >300 mg/dl) levels of triglyceride. The column used in this method was ACQUITY UPLC BEH C18 column (2.1 × 100 mm I.D., 1.7 μm). A gradient elution of mobile phase A (10 mM ammonium formate and 0.04% formic acid in water) and mobile phase B (acetonitrile) was used with a flow rate of 0.4 ml/min and run time of 5 min. The transitions of m/z 436.3 → 285.2 for SMV, m/z 437.2 → 303.2 for SMV-A, m/z 559.2 → 440.3 for ATV, m/z 575.4 → 440.3 for 2-OH-ATV and 4-OH-ATV, m/z 482.3 → 258.1 for RSV, and m/z 412.3 → 224.2 for fluvastatin (internal standard, IS) were determined by Selected Reaction Monitoring (SRM) method to detect transitions ions in the positive ion mode. The assay has a linear range of 0.25 (LLOQ) -100 ng/ml for all six analytes. Accuracy (87-114%), precision (3-13%), matrix effect (92-110%), and extraction recovery (88-100%) of the assay were within the 15% acceptable limit of FDA Guidelines in variations for plasma with both low and high triglyceride levels. The method was used successfully for the quantification of SMV, ATV, RSV, and their active metabolites in human plasma samples collected for an ongoing clinical pharmacokinetic and pharmacodynamic study on patients prior to and post gastric bypass surgery (GBS).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6298799 | PMC |
http://dx.doi.org/10.1016/j.jpba.2018.10.045 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!