Background: The use of gastric tubes in newborns admitted to a neonatal intensive care unit is fairly high, and there is a risk of serious complications related to this procedure.

Purpose: Considering the need to find a method that does not involve the patient's exposure to radiation, this study aimed to evaluate the diagnostic accuracy of ultrasonography for verifying gastric tube placement in newborns.

Methods: This was a prospective, double-blind, observational study performed in a neonatal intensive care unit, in which 159 infants had gastric intubation using ultrasound examination and radiological imaging, to verify positioning. Results were analyzed in terms of diagnostic accuracy.

Results: The tubes were correctly positioned in 157 cases (98.7%), according to radiological images, and in 156 cases (98.1%), according to ultrasound. The sensitivity analysis was 0.98 and the positive predictive value was 0.99. It was not possible to perform a specificity analysis, as there were not enough negative cases in the sample.

Implications For Practice: The use of ultrasonography to identify correct positioning of gastric tubes in infants and newborns shows good sensitivity.

Implications For Research: It was not possible to evaluate the ultrasonography specificity; further studies with greater samples are probably necessary, so that this objective can be achieved.Video Abstract available at https://journals.lww.com/advancesinneonatalcare/Pages/videogallery.aspx?videoId=29&autoPlay=true.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ANC.0000000000000553DOI Listing

Publication Analysis

Top Keywords

ultrasonography verifying
8
verifying gastric
8
gastric tube
8
tube placement
8
gastric tubes
8
neonatal intensive
8
intensive care
8
care unit
8
gastric
5
ultrasonography
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!