Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We aimed to identify factors such as pre-arthroscopy and intra-operative variables that were associated with failure of hip arthroscopy as a joint preserving operation. We performed a retrospective analysis of a database containing 344 consecutive hip arthroscopies performed at our institution. Forty-four hips were identified that underwent a subsequent arthroplasty procedure following their hip arthroscopy (cases). Sixty-six control hips (hip arthroscopy with no subsequent arthroplasty) were randomly selected from the same database. Cases and controls were matched for age, sex and follow-up ( = 0.59, 0.48, 0.10, respectively). Pre-operative radiographs/MRI scans plus intra-operative findings were analysed to identify factors associated with failure. Both a lower centre edge angle and higher acetabular index on pre-operative radiographs were associated with higher rates of failure ( < 0.001). The presence of any acetabular wear at operation was also associated with failure ( < 0.001). Highest rates of failure were seen in hips with both features of dysplasia on pre-operative radiographs and any intra-operative acetabular wear (relative risk: 5, odds ratio: 9.13, < 0.001). Dysplastic features on pre-operative radiographs and the finding of acetabular wear at hip arthroscopy increase the risk of subsequent arthroplasty. Identification of these features pre-operatively with evolving imaging techniques would improve the results of hip arthroscopy as joint preserving surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6206686 | PMC |
http://dx.doi.org/10.1093/jhps/hny020 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!