A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Merete BioBall system in hip revision surgery: A systematic review. | LitMetric

The Merete BioBall system in hip revision surgery: A systematic review.

Orthop Traumatol Surg Res

Orthopedics Surgery and Traumatology Department, Dr Peset University Hospital, avenue Gaspar Aguilar 90, 47017 Valencia, Spain.

Published: December 2018

Background: Modular hip arthroplasty is widely recognized in hip surgery; nevertheless, despite advances in prosthetic design, the incidence of hip revision surgery is increasing. In these procedures, a modular adapter that engages the femoral stem and the modular femoral head could be useful in order to protect the neck-head junction and restore preoperative biomechanics and soft tissue tension when the femoral or acetabular component should be retained. The Merete™ BioBall™ system (Merete Medical, Berlin, Germany) could fill this need. However the literature regarding this device is sparse, therefore we performed a systematic review to analyze: the indications for its use and clinical results and the causes of second revision and survival in hip revision surgery, mainly focus in complications of its use.

Materials And Methods: Databases including PubMed and Google Scholar were searched for English-language articles published between 01/01/1999 and 01/04/2017, using search terms related to the system Merete™ BioBall™. Studies that reported the clinical use of the Merete™ BioBall™ system in hip revision surgery were selected. Data related to the indications, characteristics of the implant, clinical results, causes of second revision and survival were gathered.

Results: A total of 14 studies with a level IV evidence were analyzed. Information related to the implant was provided in 194 cases. Isolated acetabular revision was the main indication of implant use (139/194 [71.6%]). The most common combination used was the standard implant (69/110 specified [59.4%]), 3XL length (28/107 specified [26.2%]) with 32mm metal head (58/187 specified [31%]). After a follow-up ranging from 2 to 97 months, there were 16 complications, thirteen (81,2%) were revised, including one neck fracture of the stem (6.25%), two ceramic head fractures (12,5%) and six recurrent dislocations (37,5%). Implant survival was 92.8% at 52.5 months of follow-up in the longest published series. Clinical and functional results were provided in a heterogeneous way.

Conclusions: There is insufficient evidence to recommend for or contraindicate the use of the Merete™ BioBall™ system. The Isolated acetabular revision was the main indication of implant use. When dislocation is the indication of its use the rate of second revision is high. Some important complications possibly related with the implant design have been reported but as isolated cases. The neck adapter failure or corrosion phenomena have not been reported. Further prospective and controlled trials are needed to assess the use of this type of implant and its survival.

Level Of Evidence: Level III systematic review of case series.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2018.06.016DOI Listing

Publication Analysis

Top Keywords

hip revision
16
revision surgery
16
merete™ bioball™
16
systematic review
12
bioball™ system
12
second revision
12
revision
9
system hip
8
clinical second
8
revision survival
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!