N-nitrosomorpholine in potable reuse.

Water Res

Water Quality Research and Development Division, Southern Nevada Water Authority, P.O. Box 99954, Las Vegas, NV, 89193-9954, USA. Electronic address:

Published: January 2019

As potable reuse guidelines and regulations continue to develop, the presence of N-nitrosamines is a primary concern because of their associated health concerns. In this study, bench-, pilot-, and full-scale tests were conducted to focus on the occurrence and treatment of N-nitrosomorpholine (NMOR) in United States (U.S.) potable reuse systems. Out of twelve U.S. wastewater effluents collected, ambient NMOR was detected in eleven (average = 20 ± 18 ng/L); in contrast, only two of the thirteen surface water and stormwater samples had NMOR. Across all of these samples maximum formation potential by chloramination produced an average increase of 3.6 ± 1.8 ng/L. This result underscores the need to understand the sources of NMOR as it is not likely a disinfection byproduct and it is not known to be commercially produced within the U.S. At the pilot-scale, three potable reuse systems were evaluated for ambient NMOR with oxidation (i.e., chlorination and ozonation), biofiltration, and granular activated carbon (GAC). Both pre-oxidation and biofiltration were ineffective at mitigating NMOR during long-term pilot plant operation (at least eight-months). GAC adsorbers were the only pilot-scale treatment to remove NMOR; however, complete breakthrough occurred rapidly from <2000 to 10,000 bed volumes. For comparison, a full-scale reverse osmosis (RO) potable reuse system was monitored for a year and confirmed that RO effectively removes NMOR. Systematic bench-scale UV-advanced oxidation experiments were undertaken to assess the mitigation potential for NMOR. At a fluence dose of 325 ± 10 mJ/cm UV alone degraded 90% of the NMOR present. The addition of 5 mg/L hydrogen peroxide did not significantly decrease the UV dose required for one-log removal. These data illustrate that efficient NMOR removal from potable reuse systems is limited to RO or UV treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2018.10.010DOI Listing

Publication Analysis

Top Keywords

potable reuse
16
reuse systems
8
ambient nmor
8
nmor
7
n-nitrosomorpholine potable
4
reuse
4
reuse potable
4
reuse guidelines
4
guidelines regulations
4
regulations continue
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!