A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a near-zero fluoroscopic approach for catheter ablation in patients with congenital heart disease. | LitMetric

Evaluation of a near-zero fluoroscopic approach for catheter ablation in patients with congenital heart disease.

J Interv Card Electrophysiol

Electrophysiology Section, Cardiology Department, Hospital Universitari i Politècnic La Fe, Área de Enfermedades Cardiovasculares, Planta 4-Torre F, Av. Fernando Abril Martorell, 106, 46026, Valencia, Spain.

Published: December 2019

Purpose: Radiation exposure (RE) is a matter of concern for patients with congenital heart disease (CHD) who not infrequently need multiple interventional procedures under fluoroscopy guidance. We sought to evaluate the safety and feasibility of a minimally fluoroscopic approach in patients with CHD undergoing catheter ablation using a new image integration module (IIM).

Methods: Consecutive patients with CHD undergoing catheter ablation using the Carto Univu™ IIM were included. A near-zero fluoroscopy procedure was defined by an effective dose (ED) ≤ 1 mSv. RE parameters (total fluoroscopy time [TFT], total dose area product [tDAP], and ED), ablation outcomes, and complications were evaluated.

Results: Fifty-five patients with CHD underwent 63 ablation procedures (supraventricular tachycardia, n = 53; ventricular tachycardia, n = 10). The CHD was simple in 25%, moderate in 42%, and complex in 33%. The use of the IIM resulted in very low levels of RE (median TFT 0.13 min [IQR 0-1.04], median tDAP 54.5 cGy cm [IQR 9.5-176.4], median ED 0.136 mSv [IQR 0.02-0.49]). Patients with complex CHD had significantly higher RE when compared with patients with simple and moderate defects. A total of 56/63 ablation procedures (89%) were performed with an ED ≤ 1 mSv. One patient developed sinus node dysfunction requiring pacemaker implantation.

Conclusions: The use of a minimally fluoroscopic approach was safe and feasible resulting in very low RE during catheter ablation of patients with CHD. A near-zero fluoroscopy ablation was possible in up to 89% of the procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-018-0467-3DOI Listing

Publication Analysis

Top Keywords

catheter ablation
16
patients chd
16
fluoroscopic approach
12
ablation
8
patients
8
ablation patients
8
patients congenital
8
congenital heart
8
heart disease
8
minimally fluoroscopic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!