Background: Tachyarrhythmias and bradyarrhythmias affect 20%-50% of adult patients with tetralogy of Fallot (TOF) and some of these patients will require cardiac implantable electronic devices (CIED) such as pacemaker and/or internal cardioverter defibrillator.

Methods: The Mayo Adult Congenital Heart Disease database was queried for patients with repaired TOF and history of CIED implantation, 1990-2017. The study objectives were: (1) determine the occurrence of device-related complications defined as lead failure, lead recall, device infection and lead thrombus; and (2) determine the occurrence and risk factors for defibrillator shock.

Results: There were 99 patients (age 46±14 years and 66 (66%) men) with CIED, and the CIEDs were 41 (41%) pacemakers and 73 (73%) defibrillators. Indication for defibrillator implantation was for primary prevention in 28 (38%) and secondary prevention in 45 (62%). Device-related complications occurred in 20 (20%) patients (lead failure 17, lead recall 4, device infection 12 and thrombus 3). Twenty-five per cent of all device infections occurred within 30 days from the time of device generator change. Annualised rates of appropriate and inappropriate shocks were 5.7% and 6.2%, respectively. The use of class III antiarrhythmic drug was protective against defibrillator shock.

Conclusion: The current study provides useful outcome data to aid patient counselling and clinical decision-making. Further studies are required to explore ways to decrease the risk of postprocedural infection after device generator change, and to determine which patients will benefit from empirical antiarrhythmic therapy as a strategy to decrease incidence of inappropriate defibrillator shock.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6658101PMC
http://dx.doi.org/10.1136/heartjnl-2018-314072DOI Listing

Publication Analysis

Top Keywords

cardiac implantable
8
implantable electronic
8
electronic devices
8
tetralogy fallot
8
patients will
8
determine occurrence
8
device-related complications
8
lead failure
8
failure lead
8
lead recall
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!