Background: Echocardiography is regarded as the gold standard for diagnosis of bicuspid aortic valve (BAV), yet diagnostic accuracy has been evaluated previously only in single-center studies. We systematically evaluated the accuracy of BAV diagnosis in a large healthcare system of multiple echocardiography laboratories.
Methods And Results: Aurora Health Care is a multihospital, multi-clinic system across the state of Wisconsin encompassing 33 inpatient and outpatient echocardiography laboratories with 39 cardiologist readers and 72 sonographers. As all laboratories store echocardiograms in one database, we queried all patients with "bicuspid aortic valve" diagnosis on echocardiography. Echocardiograms were classified as "BAV" or "possible BAV" based on initial reader confidence. An expert review panel categorized each as BAV, no BAV, or Indeterminate. Of the 745 cases identified, 589 (79.1%, initial reader interpretation: n = 494 "BAV," n = 95 "possible") were BAV. A high level of agreement (84%) was present in BAV diagnosis. There were 156 (20.9%) echocardiograms that were no BAV (8.4%) or Indeterminate (12.4%). We identified three common reasons for misdiagnosis: poor image quality (n = 70, 44.9%), leaflet calcium (n = 44, 28.2%), and oblique axis imaging (n = 33, 21.1%). A clear reason for misclassification was not elucidated in nine cases (n = 9, 5.7%).
Conclusions: This is the first study to evaluate BAV accuracy across a community health system with multiple echocardiography laboratories and a heterogeneous group of readers and sonographers. We establish a high degree of accuracy of echocardiography in BAV diagnosis and draw attention to common echocardiographic pitfalls that lead to BAV misclassification, highlighting opportunities for education and quality improvement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/echo.14167 | DOI Listing |
Sensors (Basel)
January 2025
Department of Environmental Remote Sensing and Geoinformatics, Trier University, Universitätsring 15, 54296 Trier, Germany.
Assessing vines' vigour is essential for vineyard management and automatization of viticulture machines, including shaking adjustments of berry harvesters during grape harvest or leaf pruning applications. To address these problems, based on a standardized growth class assessment, labeled ground truth data of precisely located grapevines were predicted with specifically selected Machine Learning (ML) classifiers (Random Forest Classifier (RFC), Support Vector Machines (SVM)), utilizing multispectral UAV (Unmanned Aerial Vehicle) sensor data. The input features for ML model training comprise spectral, structural, and texture feature types generated from multispectral orthomosaics (spectral features), Digital Terrain and Surface Models (DTM/DSM- structural features), and Gray-Level Co-occurrence Matrix (GLCM) calculations (texture features).
View Article and Find Full Text PDFRadiol Cardiothorac Imaging
February 2025
From the Department of Biomedical Engineering (X.Z.) and Columbia Magnetic Resonance Research Center (CMRRC) (W.S.), Columbia University, New York, NY; Departments of Medicine (C.B.C., J.P.F.) and Radiology (J.P.F.), University of California at Los Angeles, Los Angeles, Calif; Department of Radiology, Weill Cornell Medicine, New York, NY (M.R.P.); Department of Radiology (M.R.P., S.M.D., S.J.), Department of Medicine (M.C.B., R.G.B.), Department of Epidemiology (R.G.B.), Division of Pediatric Gastroenterology, Hepatology and Nutrition, Department of Pediatrics (W.S.), and Institute of Human Nutrition (W.S.), Columbia University Irving Medical Center, 632 W 168th St, PH-17, New York, NY 10032; Department of Radiology (B.A.V., J.A.C.L.) and Division of Pulmonary and Critical Care Medicine, Department of Medicine, School of Medicine (N.N.H.), Johns Hopkins University, Baltimore, Md; Department of Radiology, University of Michigan, Ann Arbor, Mich (P.P.A.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (D.A.B.); Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC (D.C.); Departments of Radiology, Medicine, and the Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa (E.A.H.); Sections on Cardiology and Geriatrics, Department of Internal Medicine, Wake Forest University School of Medicine, Winston-Salem, NC (D.W.K.); Division of Pulmonary, Critical Care, Sleep, and Allergy (J.A.K.) and Department of Radiology, College of Medicine (M.G.M.), University of Illinois at Chicago, Chicago, Ill; Department of Radiology and Biomedical Imaging (Y.J.L., J.L.), Division of Pulmonary, Critical Care, Sleep, and Allergy, Department of Medicine, School of Medicine (P.G.W.), and Cardiovascular Research Institute (P.G.W.), University of California at San Francisco, San Francisco, Calif; Division of Pulmonary and Critical Care Medicine, Department of Medicine, Wake Forest University, Winston-Salem, NC (J.O., S.P.P.); Division of Pulmonary Medicine, Department of Medicine, Mayo Clinic, Phoenix, Ariz (V.E.O.); Department of Medicine, University of Utah, Salt Lake City, Utah (R.P.); Department of Radiology, Mayo Clinic, Rochester, Minn (J.D.S.); Department of Radiology, Hannover Medical School, Hannover, Germany (J.V.C.); and BREATH, Member of the German Center for Lung Research (DZL), Hannover, Germany (J.V.C.).
Purpose To assess the repeatability of real-time cine pulmonary MRI measures of metronome-paced tachypnea (MPT)-induced dynamic hyperinflation and its relationship with chronic obstructive pulmonary disease (COPD) severity. Materials and Methods SubPopulations and InteRmediate Outcome Measures In COPD Study (SPIROMICS) (ClinicalTrials.gov identifier no.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
The First Hospital of Tsinghua University, Tsinghua University, Beijing, China.
Background: Patients with pulmonary atresia and ventricular septal defect (PA/VSD) are prone to progressive aortic dilation. However, there are relatively few reports of progressive development of aortic aneurysm or aortic dissection in adult patients who missed early corrective surgery.
Presentation Of Cases: Case 1: A 38-year-old man with PA/VSD and a bicuspid aortic valve (BAV), underwent VSD repair, aortic valve replacement, and PA correction at age 21.
Ann Noninvasive Electrocardiol
January 2025
Division of Cardiology, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA.
Background: Electrocardiograms (EKGs) are routinely performed in pregnant patients with pre-existing cardiovascular disease. However, in pregnant patients with congenital heart disease (CHD), EKG changes during gestation have not been explored.
Methods: We performed a retrospective study of pregnant patients with CHD enrolled in the STORCC initiative.
Echo Res Pract
January 2025
Echocardiography Medical Center, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, 100029, China.
Objective: To explore the diagnostic value of crucial parameters of echocardiography for fetal bicuspid aortic valve (BAV) and improve diagnostic accuracy.
Methods: Fetuses with a prenatal suspected diagnosis of BAV were followed, and confirmed and misdiagnosed cases were obtained. Prenatal echocardiography was reviewed and analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!