Aims: The aim of this study was to assess the performance of a self-expanding valve in bicuspid aortic valve (BAV) stenosis.
Methods And Results: An international registry included a total of 712 patients with aortic stenosis treated with the ACURATE neo in bicuspid (n=54; 7.5%) or tricuspid (n=658; 92.4%) anatomy. The overall mean age was 81±5.6 years. At baseline, no significant differences were found between the two groups. BAV more frequently required both predilatation (94.4% vs. 78.1%, p=0.004) and post-dilation (57.4% vs. 38.7%, p=0.007). Moderate perivalvular regurgitation was more frequently found in patients with BAV (7.4% vs. 3.18%, p=0.0001). After propensity score matching (PSM), the rate of predilation and post-dilation was confirmed to be higher in the BAV group (94.4% vs. 66.6%, p=0.001, and 57.4% vs. 37.1%, p=0.034, respectively), while the incidence of moderate perivalvular regurgitation was similar between the two groups (BAV 3.1% vs. 5.5% in tricuspid anatomy, p=0.734). In unmatched cohorts, the 30-day outcome showed a higher rate of stroke in the BAV group (7.4% vs. 1.8%, p=0.001). After adjustment for PSM quintiles, the rate of stroke resulted in being similar (odds ratioadj 1.20, 95% confidence interval [CI]: 0.81-1.76, p=0.819). The other 30-day clinical endpoints were similar between the two populations.
Conclusions: This preliminary analysis shows that the use of the ACURATE neo in bicuspid aortic valves is feasible and has acceptable 30-day outcomes. Larger studies are needed to confirm our preliminary findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4244/EIJ-D-18-00281 | DOI Listing |
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Eur Heart J Case Rep
January 2025
Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, North Kargar Ave, Tehran 1411713138, Iran.
Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.
View Article and Find Full Text PDFCJC Open
January 2025
Department of Cardiology, Royal North Shore Hospital, Sydney, Australia.
CJC Open
January 2025
Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.