A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Operando XAFS Imaging of Distribution of Pt Cathode Catalysts in PEFC MEA. | LitMetric

Operando XAFS Imaging of Distribution of Pt Cathode Catalysts in PEFC MEA.

Chem Rec

Department of Chemistry, Graduate School of Science & Research Center for Materials Science & Integrated Research Consortium on Chemical Science, Nagoya University Furo, Chikusa, Nagoya, Aichi, 464-8602, Japan.

Published: July 2019

Three-dimensional imaging using X-ray as a probe is state-of-the-art for the characterization of heterogeneous materials. In addition to simple imaging of sample morphology, imaging of elemental distribution and chemical states provides advanced maps of key structural parameters of functional materials. The combination of X-ray absorption fine structure (XAFS) spectroscopy and three-dimensional imaging such as computed tomography (CT) can visualize the three-dimensional distribution of target elements, their valence states, and local structures in a non-destructive manner. In this personal account, our recent results on the three-dimensional XAFS imaging for Pt cathode catalysts in the membrane electrode assembly (MEA) of polymer electrolyte fuel cell (PEFC) are introduced. The distribution and chemical states of Pt cathode catalysts in MEAs remarkably change under PEFC operating conditions, and the 3D XAFS imaging revealed essential events in PEFC MEAs.

Download full-text PDF

Source
http://dx.doi.org/10.1002/tcr.201800123DOI Listing

Publication Analysis

Top Keywords

xafs imaging
12
cathode catalysts
12
three-dimensional imaging
8
distribution chemical
8
chemical states
8
imaging
7
operando xafs
4
distribution
4
imaging distribution
4
distribution cathode
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!