Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate clinical outcomes of acetabular cup position on high hip and anatomical position in total hip arthroplasty for Crowe III developmental dysplasia of hip joint.
Methods: Forty-six patients(58 hips) treated with high hip center THA from January 2010 to December 2015, including 6 males (8 hips) and 40 females(50 hips) aged from 40 to 70 years old with an average of(54.3±7.6) years old. While 20 patients(28 hips) treated with anatomical position in THA from January 2004 and December 2009 were analyzed as control, including 4 males (5 hips) and 16 females (23 hips), aged from 42 to 68 years old with an average of (53.0±7.1) years old. Operative time, blood loss, Harris score (HHS), gait analysis, Trendelanburg signal, imaging examinations and prosthesis survivorship were compared between two groups.
Results: Operative time and blood loss in high hip group(75.1±13.3) min and (108.4±47.1) ml respectively were lower than that of in anatomical position group(107.7±17.1) min and(201.0±58.6) ml respectively. There was no statistical difference in HSS score at 2 years after operation in high hip group(92.3±3.7) scores and anatomical position group(91.4±3.6) scores. No obvious meaning in lower limb differences in high hip group (3.8±2.1) mm and anatomical position group (3.5±1.6) mm. The vertical distance between center of rotation to teardrop in high hip group(31.6±7.8) mm was higher than that of anatomical group(19.3±7.4) mm;while there was no significant differences in horizontal distance between high hip group (30.1±7.7) mm and anatomical group(29.4±7.5) mm. There was no statistical significance in prosthesis survivorship. The gait was good without lameness and positive features of Trendelanburg signal caused by insufficient of abductor.
Conclusions: For Crowe III DDH, a high hip center cementless cup without bone graft is a liable method with good function and high rate of prosthesis survivorship. And satisfying short-term clinical and radiographic results could be achieved by this method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3969/j.issn.1003-0034.2018.10.009 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!