A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Real-world effectiveness evaluation of budesonide/formoterol Spiromax for the management of asthma and chronic obstructive pulmonary disease in the UK. | LitMetric

Objectives: Budesonide/formoterol (BF) Spiromax is an inhaled corticosteroid/long-acting β-agonist fixed-dose combination (FDC) inhaler, designed to minimise common inhaler errors and provide reliable and consistent dose delivery in asthma and chronic obstructive pulmonary disease (COPD). We evaluated non-inferiority of BF Spiromax after changing from another FDC inhaler, compared with continuing the original inhaler.

Methods: Patients with asthma and/or COPD who switched to BF Spiromax were matched (1:3) with non-switchers. Data were obtained from the Optimum Patient Care Research Database and Clinical Practice Research Datalink in the UK. The primary end point was the proportion of patients achieving disease control (using the risk domain control (RDC) algorithm); secondary end points were: exacerbation rate, short-acting β-agonist (SABA) use and treatment stability (achieved RDC; no maintenance treatment change). Non-inferiority was defined as having 95% CI lower bound above -10%, using conditional logistic regression and adjusted for relevant confounders.

Results: Comparing 385 matched patients (asthma 253; COPD 132) who switched to BF Spiromax with 1091 (asthma 743; COPD 348) non-switchers, non-inferiority of BF Spiromax in RDC was demonstrated (adjusted difference: +6.6%; 95% CI -0.3 to 13.5). Among patients with asthma, switchers to BF Spiromax versus BF Turbuhaler reported fewer exacerbations (adjusted rate ratio (RR) 0.76;95% CI 0.60 to 0.99; p=0.044); were less likely to use high daily doses of SABA (adjusted OR 0.71;95% CI 0.52 to 0.98; p=0.034); used fewer SABA inhalers (adjusted RR 0.92;95% CI 0.86 to 0.99; p=0.019); and were more likely to achieve treatment stability (adjusted OR 1.44;95% CI 1.02 to 2.04; p=0.037). No significant differences in these end points were seen among patients with COPD.

Conclusions: Among UK patients with asthma and COPD, real-world use of BF Spiromax was non-inferior to BF Turbuhaler in terms of disease control. Among patients with asthma, switching to BF Spiromax was associated with reduced exacerbations, reduced SABA use and improved treatment stability versus continuing on BF Turbuhaler.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6224753PMC
http://dx.doi.org/10.1136/bmjopen-2018-022051DOI Listing

Publication Analysis

Top Keywords

patients asthma
20
treatment stability
12
spiromax
9
budesonide/formoterol spiromax
8
asthma
8
asthma chronic
8
chronic obstructive
8
obstructive pulmonary
8
pulmonary disease
8
fdc inhaler
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!