A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Four Fixation Points of the Axis: Technique and Case Report. | LitMetric

Background: Instrumentation of the axis can be accomplished through a variety of techniques including transarticular screw fixation, pars and pedicle screw fixation, translaminar screw fixation, and posterior wiring. We report on the evolution of the axial 4-screw technique.

Methods: Retrospective case review. After exposure of posterior spinal elements, the medial and superior walls of the C2 pedicle were identified from within the spinal canal. A high-speed drill was then advanced under lateral fluoroscopy, which guided craniocaudal angulation. Medial angulation was based on anatomic landmarks and preoperative imaging. This was followed by placement of translaminar screws according to the technique described by Wright. When extending the construct into the subaxial spine or the occiput, lateral connectors are placed in translaminar screws, which are usually more offset. The rod is directly connected to the pedicle screws, which are usually more in alignment with the subaxial/occipital instrumentation.

Results: Two male patients ages 56 and 58 underwent posterior instrumentation of the axis employing a combination of pedicle and laminar polyaxial screws. Indications included multilevel spinal cord compression and deformity in a patient with Down syndrome and cervical meningioma, respectively. Follow-up was 1 year and 5 years, respectively. Medical complications (N = 2) occurred in the patient with Down syndrome resulting in prolonged intubation with tracheostomy placement. Reduction was maintained in both patients at last follow-up. There were no neurologic, vascular, or instrumentation related complications.

Conclusions: The axis serves as a versatile anchor point and offers 4 potential points of fixation. Lateral connectors play a crucial role and allow for incorporation of the C2 screws with the rest of the construct. Local anatomy will dictate the necessity and ability to place instrumentation and detailed preoperative planning is of paramount importance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6200057PMC
http://dx.doi.org/10.14444/5073DOI Listing

Publication Analysis

Top Keywords

screw fixation
12
instrumentation axis
8
translaminar screws
8
lateral connectors
8
patient syndrome
8
fixation
5
screws
5
fixation points
4
axis
4
points axis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!