A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Mikrochim Acta

Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, Shaanxi Normal University, Xi'an, 710062, China.

Published: October 2018

CdTe quantum dots (QDs) were integrated with polyethyleneimine-coated carbon dots (PEI-CDs) to form a dually emitting probe for heparin. The red fluorescence of the CdTe QDs is quenched by the PEI-CDs due to electrostatic interactions. In the presence of heparin, the blue fluorescence of PEI-CDs remains unaffected, while its quenching effect on the fluorescence of CdTe QDs is strongly reduced. A ratiometric fluorometric assay was worked out. The ratio of the fluorescences at 595 and 436 nm serves as the analytical signal. Response is linear in the concentration range of 50-600 ng·mL (0.1-1.2 U·mL) of heparin. The limit of detection is 20 ng·mL (0.04 U·mL). This makes the method a valuable tool for heparin monitoring during postoperative and long-term care. This assay is relatively free from the interference by other analogues which commonly co-exist with heparin in samples, and it is more robust than single-wavelength based assays. Graphical abstract In the presence of heparin, the fluorescence of polyethyleneimine-coated carbon dots (PEI-CDs) at 436 nm remains unaffected, while its quenching effect on the fluorescence of CdTe at 595 nm is strongly reduced.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-018-3061-6DOI Listing

Publication Analysis

Top Keywords

polyethyleneimine-coated carbon
12
ratiometric fluorometric
8
quantum dots
8
carbon dots
8
dots pei-cds
8
presence heparin
8
remains unaffected
8
unaffected quenching
8
quenching fluorescence
8
fluorescence cdte
8

Similar Publications

Simultaneous immunodetection of multiple cervical cancer biomarkers based on a signal-amplifying redox probes/polyethyleneimine-coated gold nanoparticles/2D tungsten disulfide/graphene oxide nanocomposite platform.

Bioelectrochemistry

December 2024

Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand. Electronic address:

To advance cervical cancer diagnostics, we propose a state-of-the-art label-free electrochemical immunosensor designed for the simultaneous detection of multiple biomarker proteins (p16, p53, and Ki67). This immunosensor is constructed using a polyethyleneimine-coated gold nanoparticles/2D tungsten disulfide/graphene oxide (PEI-AuNPs/2D WS/GO) composite-modified three-screen-printed carbon electrode (3SPCE) array. The 2D WS/GO hybrid provides a large specific surface area for supporting well-dispersed PEI-AuNPs and adsorbed redox-active species, enhancing overall performance.

View Article and Find Full Text PDF

In this work, we report, for the first time, the construction of a label-free electrochemical immunosensor for highly sensitive detection of a new lung cancer biomarker, GM2 activator protein (GM2AP). A polyethyleneimine-coated gold nanoparticle (PEI-AuNP) and phosphomolybdic acid (PMA) modified electrode is developed as a novel redox platform for GM2AP detection. A PEI-AuNP film-modified screen-printed carbon electrode, as a signal amplifier support, was successfully fabricated for the adsorption of PMA redox molecules and is used for signal amplification.

View Article and Find Full Text PDF

A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Mikrochim Acta

October 2018

Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, Shaanxi Normal University, Xi'an, 710062, China.

CdTe quantum dots (QDs) were integrated with polyethyleneimine-coated carbon dots (PEI-CDs) to form a dually emitting probe for heparin. The red fluorescence of the CdTe QDs is quenched by the PEI-CDs due to electrostatic interactions. In the presence of heparin, the blue fluorescence of PEI-CDs remains unaffected, while its quenching effect on the fluorescence of CdTe QDs is strongly reduced.

View Article and Find Full Text PDF

Liquid crystal and gold nanoparticles applied to electrochemical immunosensor for cardiac biomarker.

Biosens Bioelectron

September 2014

Laboratory of Biosensors, Department of Chemistry, Federal University of Santa Catarina, 88040-900 Florianópolis, Santa Catarina, Brazil. Electronic address:

A label-free electrochemical immunosensor based on the ionic liquid crystal (E)-1-decyl-4-[(4-decyloxyphenyl)diazenyl]pyridinium bromide (Br-Py) coated on a glassy carbon electrode (GCE) for the quantitative detection of myoglobin (Mb), a cardiac marker for acute myocardial infarction, is reported herein for the first time. The monoclonal anti-myoglobin antibody (ab-Mb) was covalently immobilized using glyoxal on a film of polyethyleneimine-coated gold nanoparticles (AuNP-PEI). The proposed method for Mb detection is based on voltammetric suppression of the Br-Py signal when the immunosensor was incubated with Mb antigen.

View Article and Find Full Text PDF

Loss of calcium homeostasis leads to progressive phase of chlordecone-potentiated carbon tetrachloride hepatotoxicity.

Toxicol Appl Pharmacol

September 1993

Division of Pharmacology and Toxicology, College of Pharmacy and Health Sciences, Northeast Louisiana University, Monroe 71209-0470.

Earlier work has shown increased hepatocellular free Ca2+ levels in rats receiving a single subtoxic dose of CCl4 after dietary pretreatment with nontoxic (10 ppm, 15 days) levels of chlordecone (CD), indicating a significant perturbation of Ca2+ homeostasis in the interactive toxicity of CD + CCl4 combination treatment. In the present study, the mitochondrial and microsomal ability to sequester Ca2+ as well as plasma membrane translocase activity was investigated, since it is known that cells maintain normal Ca2+ homeostasis by these mechanisms. Hepatic plasma membrane Ca(2+)-ATPase (high and low affinity components) as well as 45Ca uptake by mitochondria and microsomes was measured using a range of calcium concentrations in Ca(2+)-EGTA-buffered medium at different time points after a single ip administration of CCl4 (100 microliters/kg).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!