Calibration and reproducibility of quantitative F-FDG PET measures are essential for adopting integral F-FDG PET/CT biomarkers and response measures in multicenter clinical trials. We implemented a multicenter qualification process using National Institute of Standards and Technology-traceable reference sources for scanners and dose calibrators, and similar patient and imaging protocols. We then assessed SUV in patient test-retest studies. Five F-FDG PET/CT scanners from 4 institutions (2 in a National Cancer Institute-designated Comprehensive Cancer Center, 3 in a community-based network) were qualified for study use. Patients were scanned twice within 15 d, on the same scanner ( = 10); different but same model scanners within an institution ( = 2); or different model scanners at different institutions ( = 11). SUV was recorded for lesions, and SUV for normal liver uptake. Linear mixed models with random intercept were fitted to evaluate test-retest differences in multiple lesions per patient and to estimate the concordance correlation coefficient. Bland-Altman plots and repeatability coefficients were also produced. In total, 162 lesions (82 bone, 80 soft tissue) were assessed in patients with breast cancer ( = 17) or other cancers ( = 6). Repeat scans within the same institution, using the same scanner or 2 scanners of the same model, had an average difference in SUV of 8% (95% confidence interval, 6%-10%). For test-retest on different scanners at different sites, the average difference in lesion SUV was 18% (95% confidence interval, 13%-24%). Normal liver uptake (SUV) showed an average difference of 5% (95% confidence interval, 3%-10%) for the same scanner model or institution and 6% (95% confidence interval, 3%-11%) for different scanners from different institutions. Protocol adherence was good; the median difference in injection-to-acquisition time was 2 min (range, 0-11 min). Test-retest SUV variability was not explained by available information on protocol deviations or patient or lesion characteristics. F-FDG PET/CT scanner qualification and calibration can yield highly reproducible test-retest tumor SUV measurements. Our data support use of different qualified scanners of the same model for serial studies. Test-retest differences from different scanner models were greater; more resolution-dependent harmonization of scanner protocols and reconstruction algorithms may be capable of reducing these differences to values closer to same-scanner results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6495239PMC
http://dx.doi.org/10.2967/jnumed.118.209544DOI Listing

Publication Analysis

Top Keywords

f-fdg pet/ct
16
95% confidence
16
confidence interval
16
scanners institutions
12
average difference
12
scanners
8
suv
8
scanner model
8
model scanners
8
normal liver
8

Similar Publications

Purpose: The study aimed to compare the diagnostic accuracy of Ga-DOTA-FAPI-04 (Ga-FAPI) and F-FDG PET/CT for peritoneal carcinomatosis (PC) in patients with various types of cancer.

Methods: The study enrolled 113 patients with suspected peritoneal malignancy, each of whom underwent Ga-FAPI and F-FDG PET/CT scans. Lesions in all patients were confirmed through pathology or radiological follow-up.

View Article and Find Full Text PDF

Unusual presentation of esophageal tuberculosis: a case study.

BMC Infect Dis

January 2025

Department of Radiation Oncology, Cancer Treatment Center, The Second Affiliated Hospital of Hainan Medical University, 368 Yehai Road, Haikou, 570311, China.

Background: Esophageal ulcers can arise not only from malignant lesions but also from benign diseases, such as tuberculosis. These ulcers may mimic the radiological features of esophageal malignancy or tuberculosis on PET/CT, leading to diagnostic challenges.

Case Presentation: A 59-year-old woman was admitted to our hospital with a month-long history of progressive painful swallowing, fatigue, and loss of appetite.

View Article and Find Full Text PDF

Imaging is used for lymphoma detection, Ann Arbor/Lugano staging, and treatment response assessment. [F]FDG PET/CT should be used for most lymphomas, including Hodgkin lymphoma, aggressive/high-grade Non-Hodgkin lymphomas (NHL) such as diffuse large B-cell lymphoma, and many indolent/low-grade NHLs such as follicular lymphoma. Apart from these routinely FDG-avid lymphomas, some indolent NHLs, such as marginal zone lymphoma, are variably FDG-avid; here, [F]FDG PET/CT is an alternative to contrast-enhanced CT at baseline and may be used for treatment response assessment if the lymphoma was FDG-avid at baseline.

View Article and Find Full Text PDF

Prognostic value of [F]FDG PET/CT in patients with idiopathic pulmonary fibrosis.

Sci Rep

January 2025

Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.

The study investigates the prognostic value of [F]fluorodeoxyglucose (FDG) PET/CT in patients with idiopathic pulmonary fibrosis (IPF). A total of 346 IPF patients who underwent FDG PET/CT between 2007 and 2020 were analyzed. Pulmonary FDG uptake [target to background ratio (TBR)] was binarized by optimal cut-off value based on survival analysis.

View Article and Find Full Text PDF

Objective: Neoadjuvant chemotherapy (NACT) has been the primary treatment method for patients with local advanced breast cancer. A pathological complete response (pCR) to therapy correlates with better overall disease prognosis. Magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) have been widely used to monitor the response to NACT in breast cancer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!