Introduction: We performed a single-center nonrandomized study on patients who underwent endovascular aneurysm repair using polymer-filled or other self-expanding endografts.
Methods: Consecutive patients with asymptomatic infrarenal abdominal aortic aneurysms who underwent endovascular repair were retrospectively reviewed. They were divided into a polymer-filled ( n = 20) or self-expanding group ( n = 42). Baseline characteristics, operative mortality and morbidity, and follow-up data were compared.
Results: Aneurysm diameter, neck and iliac morphologies did not differ between the two groups. Technical success was 100%. The 30-day mortality was 0% and 2.4% in the polymer-filled and self-expanding group, respectively. At a mean follow-up of 17 months, the changes in sac size were -2.1 mm and -5.1 mm ( p = 0.144) at one year, and -3.5 mm and -7.7 mm ( p = 0.287) at 2 years in the polymer-filled and self-expanding group, respectively. The polymer-filled group had 7 (35%) type II endoleaks, and the self-expanding group had 1 (2.4%) type Ia and 13 (31%) type II endoleaks. Neck diameter remained stable in the polymer-filled stent-grafts whereas there was progressive neck degeneration in the self-expanding group. The rates of reintervention and overall survival were similar in both groups. The presence of an endoleak was the only predictor of non-regression of the aneurysm (odds ratio = 17.00, 95% confidence interval: 4.46-64.88, p < 0.001).
Conclusion: Polymer-filled endografts had similar safety, effectiveness, and durability to other self-expanding endografts. The major advantage is the small iliofemoral access. They also have the potential long-term benefit of a more stable neck.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0218492318810108 | DOI Listing |
Cardiovasc Revasc Med
December 2024
Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:
Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.
View Article and Find Full Text PDFAnn Ital Chir
December 2024
Department of Cardiovascular Surgery, Shaoxing People's Hospital, 312000 Shaoxing, Zhejiang, China.
Catheter Cardiovasc Interv
December 2024
Cardiology Department, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Background: The management of Transcatheter Aortic Valve Implantation (TAVI) patients with a small aortic annulus (SAA) postures a substantial challenge, increasing the risk of patient- prosthesis mismatch (PPM) and overall mortality.
Aims: This study aimed to compare the hemodynamic and clinical outcomes of transcatheter balloon-expandable valve (BEV) versus transcatheter self-expandable valve (SEV) in SAA.
Methods: We conducted propensity score matching (PSM) of severe AS patients with SAA who underwent trans-femoral TAVR and enrolled to the Israeli TAVR registry between the years 2008 and 2023.
Tech Coloproctol
December 2024
Department of Colorectal Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China.
Objective: To investigate the optimal interval between self-expanding metal stent (SEMS) placement and radical surgery in patients with obstructive colorectal cancer.
Method: In this study, a retrospective research design was used to select 125 patients with obstructive colorectal cancer who underwent colonoscopic SEMS placement with subsequent radical surgery between February 2011 and November 2022 at Shanghai Changhai Hospital. In addition, their clinical data and therapeutic efficacy were examined.
Surg Endosc
December 2024
Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Background And Aims: Self-expanding metal stents (SEMSs) are effective for symptom palliation in patients with esophageal obstruction. However, their placement can lead to adverse events such as stent migration and restenosis. A novel fully covered SEMS (FCSEMS) with antimigration properties has been developed to address these issues.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!