Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To determine the relationship between maternal serum uric acid levels and fetal/neonatal complications in women with pre-eclampsia/eclampsia, and to establish a predictive threshold value.
Methods: A diagnostic test and historical cohort study conducted by prospective cross-sectional data collection on pregnant women with pre-eclampsia/eclampsia at Hue University Hospital, Vietnam, between March 2015 and July 2017. Pre-eclampsia was diagnosed based on ACOG criteria. Serum uric acid levels were measured by enzymatic colorimetric testing using a Cobas c 501 analyzer (Roche Diagnostics, Mannheim, Germany). Fetal complications included intrauterine growth restriction, preterm delivery, fetal death, and neonatal death.
Results: There were 205 women enrolled. Serum uric acid at a cutoff of 393 μmol/L is a good predictor of fetal/neonatal complications (AUC 0.752), with 64.4% sensitivity and 79.5% specificity. High uric acid level (≥393 μmol/L) resulted in increased risk of preterm birth (OR 6.367, 95% CI 3.009-13.084), low Apgar scores (OR 5.514, 95% CI 1.877-16.198), intrauterine growth restriction (OR 7.188, 95% CI 3.592-14.382), and neonatal death (OR 7.818, 95% CI 1.614-37.867). There was no relationship between uric acid level and fetal death (OR 1.803, 95% CI 0.355-9.168).
Conclusions: Maternal serum uric acid concentration is a good predictor of fetal/neonatal outcomes in women with pre-eclampsia/eclampsia.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379648 | PMC |
http://dx.doi.org/10.1002/ijgo.12697 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!