Background: The use of measurement instruments in physiotherapy has been recommended in clinical practice guidelines to improve evidence-based practice. The aims of the study were (a) to describe the current use of measurement instruments by physiotherapists working in Germany and (b) to investigate the facilitators and barriers to use measurement instruments.
Methods: This cross-sectional study used a nationwide online survey, which was accessible to all physiotherapists working in Germany.
Results: In total, 522 adult physiotherapists working in Germany completed the questionnaire. The mean age of the respondents was 38 years, 63% were female, and 53% had >10 years of work experience. Thirty-one percent of the respondents used measurement instruments in ≥80% of their patients, and 26% used measurement instruments in ≤20%. Measurement instruments were used for diagnostic and prognostic purposes by 69% and 22% of respondents, respectively. The three most frequently reported measurement instruments were "goniometer" (n = 254), some kind of a "visual/numeric analogue scale" (n = 139), and the "manual examination of muscle-strength" (n = 54). Seven of the 13 most stated measurement instruments measure activities or participation. The most important facilitator was physiotherapists' positive attitudes towards measurement instruments. Two out of three respondents reported having sufficient knowledge and skills to apply measurement instruments in clinical practice. The most pronounced barriers were insufficient additional financial compensations and requiring extra time to document test scores. Seventy-eight percent of the respondents could imagine using an electronic device for a user-friendly patient health record system in clinical practice.
Conclusions: The limited use of measurement instruments reported by physiotherapists working in Germany appears to be due to organisational issues, in combination with a lack of knowledge and skills needed to apply the measurement instruments, rather than due to individual or managerial reasons. To support the use of measurement instruments, sufficient time resources and adequate financial compensation are required. Educational approaches should focus on imparting patient-centred and patient-reported outcomes to quantify activities and participation. Electronic patient health record systems have potential to facilitate the application of standardised measurement instruments if the barriers identified in this survey are addressed properly.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6199696 | PMC |
http://dx.doi.org/10.1186/s12913-018-3563-2 | DOI Listing |
Ann Biomed Eng
January 2025
Carnegie Applied Rugby Research (CARR) Centre, Carnegie School of Sport, Leeds Beckett University, Leeds, UK.
Purpose: Head acceleration events (HAEs) are a growing concern in contact sports, prompting two rugby governing bodies to mandate instrumented mouthguards (iMGs). This has resulted in an influx of data imposing financial and time constraints. This study presents two computational methods that leverage a dataset of video-coded match events: cross-correlation synchronisation aligns iMG data to a video recording, by providing playback timestamps for each HAE, enabling analysts to locate them in video footage; and post-synchronisation event matching identifies the coded match event (e.
View Article and Find Full Text PDFJ Patient Rep Outcomes
January 2025
Department of Clinical Medicine, Faculty of Health, University of Copenhagen, Copenhagen, Denmark.
Background: Patient Reported Outcomes Measurement Information System Fatigue Short-Form (PROMIS-F-SF) is a self-administered, patient reported outcome (PRO) designed to assess fatigue in healthy and clinical populations and for tracking progress during treatment for disorders complicated with fatigue.
Methods: Patients in the Mental Health Service Outpatient Clinics and healthy volunteers were invited to complete a survey, which included the Danish translation of the PROMIS-F-SF, the Chalder Fatigue Scale (CFS-11), and measures of depression and anxiety. We conducted a confirmatory factor analysis of the previously suggested single-factor structure of the instrument.
J Appl Lab Med
January 2025
Eli Lilly and Company, Indianapolis, IN, United States.
Background: Blood-based biomarkers, especially P-tau217, have been gaining interest as diagnostic tools to measure Alzheimer disease (AD) pathology.
Methods: We developed a plasma P-tau217 chemiluminescent immunoassay using 4G10E2 and IBA493 as antibodies, a synthetic tau peptide as calibrator, and the Quanterix SP-X imager. Analytical validation performed in a College of American Pathologists-accredited CLIA laboratory involved multiple kit lots, operators, timepoints, and imagers.
Plant Physiol
January 2025
Max-Planck-Institute of Molecular Plant Physiology, Am Mühlenberg 1, D-14476 Potsdam-Golm, Germany.
RIBULOSE-1,5-BISPHOSPHATE CARBOXYLASE/OXYGENASE (RUBISCO) is the most abundant enzyme and CO2 bio-sequestration system on Earth. Its in vivo activity is usually determined by 14CO2 incorporation into 3-phosphoglycerate (3PGA). However, the radiometric analysis of 3PGA does not distinguish carbon positions.
View Article and Find Full Text PDFJ Wound Ostomy Continence Nurs
January 2025
Iraktânia Vitorino Diniz, MSc, RN, Doctoral Student in Nursing at the Federal University of Paraiba, Campus I - Lot. City Universitaria, João Pessoa, Paraíba 58051-900, Brazil.
Purpose: The purpose of this study was to examine health-related quality of life and adaptation of persons with a colostomy before and after use of a colostomy plug.
Design: Single group before-and-after study.
Subjects And Setting: The study sample comprised 19 people with a colostomy who attended an outpatient clinic João Pessoa, in Paraiba, Brazil.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!