Salt-Assisted Liquid-Liquid Extraction of Meconium for Analysis of Cocaine and Amphetamines by Liquid Chromatography-Tandem Mass Spectrometry.

Methods Mol Biol

MedTox Laboratories, Laboratory Corporation of America Holdings, St. Paul, MN, USA.

Published: June 2019

Meconium, the first stool of a newborn, can be analyzed to identify prenatal exposure to drugs of abuse. Meconium accumulates in a fetus during the second and third trimesters of pregnancy providing a wide window of exposure. Identification of in utero drug exposure is essential for the diagnosis and treatment of infants for dependency/withdrawal caused from the exposure. However, testing of meconium samples is often cumbersome and time-consuming. Unlike liquid samples, meconium is a viscous, semisolid, tar-like substance that needs to be individually weighed prior to extraction. Additionally, the meconium matrix is not homogeneous and not easily mixed or extracted. A method for analyzing cocaine and metabolites as well as amphetamines in meconium utilizing ceramic homogenizers prior to salt-assisted liquid-liquid extraction and liquid chromatography tandem-mass spectrometry (LC-MS/MS) is presented.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-4939-8823-5_19DOI Listing

Publication Analysis

Top Keywords

salt-assisted liquid-liquid
8
liquid-liquid extraction
8
meconium
7
extraction meconium
4
meconium analysis
4
analysis cocaine
4
cocaine amphetamines
4
amphetamines liquid
4
liquid chromatography-tandem
4
chromatography-tandem mass
4

Similar Publications

Salt assisted liquid-liquid extraction combined with dispersive liquid-liquid microextraction for the determination of 24 regulated polycyclic aromatic hydrocarbons in human serum.

J Pharm Biomed Anal

September 2024

Department of Analytical, Bioanalytical Sciences and Miniaturization, Chemistry, Biology and Innovation (CBI) UMR 8231, ESPCI Paris PSL, CNRS, PSL University, Paris,  France; Sorbonne University, Paris, France. Electronic address:

Polycyclic aromatic hydrocarbons (PAHs) are persistent organic pollutants of great concern due to their carcinogenicity and mutagenicity. Their determination in human serum, particularly in at-risk populations, is necessary but difficult because they are distributed over a wide range of polarity and are present at trace level. A new method combining salting-out assisted liquid-liquid extraction (SALLE) and dispersive liquid-liquid microextraction with solidification of floating organic drop (DLLME-SFO) adapted to a reduced volume of sample (100 µl) was developed to determine 24 PAHs in human serum.

View Article and Find Full Text PDF

Many dietary supplements claim the ability to enhance sports performance and to improve the fitness of the consumers. Occasionally, along with legal ingredients, illicit compounds may be added without being labelled, leading to unintended doping. Hence, the aim of this study was to develop an analytical method to determine a set of 12 polar (logD from -2.

View Article and Find Full Text PDF

Persistent, mobile and toxic substances have drawn attention nowadays due to their particular properties, but they are overlooked in human monitorization works, limiting the knowledge of the human exposome. In that sense, human urine is an interesting matrix since not only parent compounds are eliminated, but also their phase II metabolites that could act as biomarkers. In this work, 11 sample preparation procedures involving preconcentration were tested to ensure maximum analytical coverage in human urine using mixed-mode liquid chromatography coupled with high-resolution tandem mass spectrometry.

View Article and Find Full Text PDF

Major concerns have been raised about human exposure to endocrine-disrupting chemicals (EDCs) during pregnancy. Effective methodologies for the assessment of this exposure are needed to support the implementation of preventive measures and the prediction of negative health effects. Meconium has proven a valuable non-invasive matrix for evaluating cumulative exposure to xenobiotics during the last two trimesters of pregnancy.

View Article and Find Full Text PDF

In this study, a simple, inexpensive, selective, and fast salting-out assisted liquid-liquid extraction (SALLE) technique coupled with high-pressure liquid chromatography-diode array detection (HPLC-DAD) was developed for the extraction, preconcentration, and analysis of trace level seven multiclass pesticide residues in pasteurized and raw cow milk samples. The significant factors that affect the extent to which the target analytes are extracted, such as the type of extraction solvent and its volume, the type and concentration of salting-out salts, the pH of the solution, and the extraction time, have been investigated. Under optimum conditions, the correlation coefficient () was obtained within a range of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!