Flash glucose monitoring, an alternative to traditional self-monitoring of blood glucose (SMBG), prevents hypoglycaemic events without impacting glycated haemoglobin (REPLACE trial). Given the potential benefits, this study assessed the cost-effectiveness of using flash monitoring versus SMBG alone in patients with type 2 diabetes (T2D) receiving intensive insulin treatment in Sweden. This study used the IQVIA CORE Diabetes Model (IQVIA CDM, v8.5) to simulate the impact of flash monitoring versus SMBG over 40 years from the Swedish societal perspective. Baseline characteristics, intervention effects, and resource utilisation were derived from REPLACE; literature and Tandvårds-Läkemedelförmånsverket (TLV) sources informed utilities and costs. Scenario analyses explored the effect of key base case assumptions. In base case analysis, direct medical costs for flash monitoring use were SEK1,630,586 (€158,523) versus SEK1,459,394 (€141,902) for SMBG use. Flash monitoring led to 0.56 additional quality-adjusted life years (QALYs; 6.21 versus 5.65 SMBG) for an incremental cost-effectiveness ratio (ICER) of SEK306,082/QALY (€29,762/QALY). ICERs for all scenarios remained under SEK400,000/QALY (€38,894/QALY). Hypoglycaemia and health utility benefits due to flash glucose monitoring may translate into economic value compared to SMBG. With robust results across scenario analyses, flash monitoring may be considered cost-effective in a Swedish population of T2D intensive insulin users.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6182927 | PMC |
http://dx.doi.org/10.17925/EE.2018.14.2.80 | DOI Listing |
BMC Public Health
January 2025
Department of Medical Oncology, Dana-Farber Cancer Institute, Boston, MA, USA.
Background: Compared to older adults with breast cancer (BC), adolescents and young adults (AYAs) develop more aggressive disease necessitating more intensive therapy with curative intent, which is disruptive to planned life trajectories. The burden of unmet needs among AYA BC survivors exists in two domains: (1) symptoms (e.g.
View Article and Find Full Text PDFLangenbecks Arch Surg
January 2025
Department of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.
Purpose: Pancreatectomy patients often experience challenging fluctuations in blood glucose levels; therefore, they require a reliable monitoring system. This study aimed to determine the accuracy and acceptability of a continuous glucose monitoring (CGM) system compared with the intermittent capillary glucose test in patients who have undergone pancreatectomy.
Methods: Thirty non-diabetic pancreatectomy patients participated.
Diabetes Metab Syndr Obes
January 2025
Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210012, People's Republic of China.
Objective: To explore the efficacy and safety of intermittent use of flash glucose monitoring (FGM) for improving glycemic control in Chinese elderly patients with type 2 diabetes mellitus (T2DM).
Methods: This is a prospective observational study involving patients with T2DM aged ≥60 years. The study period spans 12 weeks, with participants wearing FGM at weeks 0, 5, and 10.
Diabetes Obes Metab
January 2025
Medical Care Center Endocrinology and Diabetology, Düsseldorf, Germany.
Aims: This study assessed efficacy and safety of the fixed ratio combination iGlarLixi 100/33 (insulin glargine 100 U/mL plus lixisenatide 33 μg/mL) in people with type 2 diabetes (PwT2D) in daily clinical practice.
Materials And Methods: This non-interventional, multicentre, prospective, single-arm 24-week study documented PwT2D with an HbA1c of 7.5%-10.
Int J Gynaecol Obstet
January 2025
Department of Obstetrics and Gynaecology, Hamdard Institute of Medical Sciences and Research, Jamia Hamdard, Delhi, India.
Objective: This study compares ambulatory glycemic profile and glycemic variability between pregnant women diagnosed with type 2 diabetes mellitus (T2DM) receiving pharmacotherapy and healthy pregnant women without diabetes and assesses their correlation with fetal outcome.
Method: This was a case-control study involving 60 pregnant women (40 with T2DM and 20 healthy controls) in the third trimester of pregnancy. A flash glucose monitor device was applied over the upper arm to obtain the ambulatory glucose profile.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!