Zygomaticomaxillary modifications in the horizontal plane induced by micro-implant-supported skeletal expander, analyzed with CBCT images.

Prog Orthod

Division of Growth and Development, Section of Orthodontics, School of Dentistry, Center for Health Science, University of California, 10833 Le Conte Avenue, Box 951668, CA, Los Angeles, 90095-1668, USA.

Published: October 2018

Background: Miniscrew-assisted rapid palatal expansion (MARPE) has been adopted in recent years to expand the maxilla in late adolescence and adult patients. Maxillary Skeletal Expander (MSE) is a device that exploits the principles of skeletal anchorage to transmit the expansion force directly to the maxillary bony structures and is characterized by the miniscrews' engagement of the palatal and nasal cortical bone layers. In the literature, it has been reported that the zygomatic buttress is a major constraint that hampers the lateral movement of maxilla, since maxilla is located medially to the zygomatic arches. The objective of the present study is to analyze the changes in the zygomatic bone, maxillary bone, and zygomatic arches and to localize the center of rotation for the zygomaticomaxillary complex in the horizontal plane after treatment with MSE, using high-resolution cone-beam computed tomography (CBCT) images.

Methods: Fifteen subjects with a mean age of 17.2 (± 4.2) years were treated with MSE. CBCT records were taken before and after miniscrew-assisted maxillary expansion; three linear and four angular parameters were identified in the axial zygomatic section (AZS) and were compared from pre-treatment to post-treatment using the Wilcoxon signed rank test.

Results: Anterior inter-maxillary distance increased by 2.8 mm, posterior inter-zygomatic distance by 2.4 mm, angle of the zygomatic process of the temporal bone by 1.7° and 2.1° (right and left side) (P < 0.01). Changes in posterior inter-temporal distance and zygomaticotemporal angle were negligible (P > 0.05).

Conclusions: In the horizontal plane, the maxillary and zygomatic bones and the whole zygomatic arch were significantly displaced in a lateral direction after treatment with MSE. The center of rotation for the zygomaticomaxillary complex was located near the proximal portion of the zygomatic process of the temporal bone, more posteriorly and more laterally than what has been reported in the literature for tooth-borne expanders. Bone bending takes place in the zygomatic process of the temporal bone during miniscrew-supported maxillary expansion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6196147PMC
http://dx.doi.org/10.1186/s40510-018-0240-2DOI Listing

Publication Analysis

Top Keywords

horizontal plane
12
zygomatic process
12
process temporal
12
temporal bone
12
zygomatic
10
skeletal expander
8
zygomatic arches
8
center rotation
8
rotation zygomaticomaxillary
8
zygomaticomaxillary complex
8

Similar Publications

Multi-Planar Cervical Motion Dataset: IMU Measurements and Goniometer.

Sci Data

January 2025

Department of Anatomy and Anthropology, Faculty of Medical & Health Sciences, Tel- Aviv University, Tel-Aviv, 699780, Israel.

This data descriptor presents a comprehensive and replicable dataset and method for calculating the cervical range of motion (CROM) utilizing quaternion-based orientation analysis from Delsys inertial measurement unit (IMU) sensors. This study was conducted with 14 participants and analyzed 504 cervical movements in the Sagittal, Frontal and Horizontal planes. Validated against a Universal Goniometer and tested for reliability and reproducibility.

View Article and Find Full Text PDF

Perovskite/silicon tandem solar cells (TSCs) are promising candidates for commercialization due to their outstanding power conversion efficiencies (PCEs). However, controlling the crystallization process and alleviating the phases/composition inhomogeneity represent a considerable challenge for perovskite layers grown on rough silicon substrates, ultimately limiting the efficiency and stability of TSC. Here, this study reports a "halide locking" strategy that simultaneously modulates the nucleation and crystal growth process of wide bandgap perovskites by introducing a multifunctional ammonium salt, thioacetylacetamide hydrochloride (TAACl), to bind with all types of cations and anions in the mixed halide perovskite precursor.

View Article and Find Full Text PDF

Assembly of graphene oxide reduced graphene oxide in a phospholipid monolayer at air-water interfaces.

Phys Chem Chem Phys

January 2025

Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence, NH91, Tehsil Dadri, G. B. Nagar, Uttar Pradesh 201314, India.

Graphene and its derivatives, such as graphene oxide (GO) and reduced graphene oxide (rGO), have propelled advancements in biosensor research owing to their unique physicochemical and electronic characteristics. To ensure their safe and effective utilization in biological environments, it is crucial to understand how these graphene-based nanomaterials (GNMs) interact with a biological milieu. The present study depicts GNM-induced structural changes in a self-assembled phospholipid monolayer formed at an air-water interface that can be considered to represent one of the leaflets of a cellular membrane.

View Article and Find Full Text PDF

Dimensions of bony Kambin's triangle pertaining to endoscopic procedure.

Med J Armed Forces India

December 2024

Senior Consultant (Neurology), NH MMI Superspeciality, Raipur, Chhattisgarh, India.

Background: Endoscopic procedures nowadays are successful, minimally invasive, and safer, with fewer intraoperative and postoperative complications and shorter hospital stays. Kambin's triangle (KT) is the three-dimensional configuration that is used as a transforaminal anatomical corridor for epidural steroid injections and endoscopic surgeries for various lumbar pathologies. This study aims to estimate the dimensions of KT and diameter of the cannula for the transforaminal surgical approaches using KT in the Chhattisgarh population.

View Article and Find Full Text PDF

Analysing the support mechanisms of the vaginal ring pessary on supine and upright MRI.

Sci Rep

December 2024

Multi-Modality Medical Imaging (M3I), TechMed Centre, University of Twente, Technohal 2384,Drienerolaan 5, Enschede, 7522NB, The Netherlands.

Vaginal pessaries have been used for millennia to alleviate symptoms of pelvic organ prolapse (POP). Despite their long-standing use, the success rate of pessary treatment is approximately 60%, and the underlying mechanisms of support are not well understood. This study aims to investigate three previously proposed hypotheses regarding the support mechanisms of pessaries, utilizing supine and upright magnetic resonance imaging (MRI): (1) support by bony structures, (2) support by levator ani muscles (LAM), and (3) the uterus keeping the pessary in place by acting as a lever.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!