Background: Prehospital medical teams are commonly required to administer a range of medications for urgent stabilisation and treatment. The safe preparation of medications during resuscitation requires attention, time and resources, and can be a source of medication error. In our two road and HEMS (Helicopter Emergency Medical Service) prehospital services, medication errors are mitigated by predrawing commonly used medications to set concentrations daily (Hunter Retrieval Service, HRS) or second-daily (CareFlight Sydney, CFS). However, there are no published data confirming that such practice is microbiologically safe.
Methods: A convenience sample of 299 predrawn medication syringes with syringe dwell times up to 48 hours were collected at the end of their operational deployment. Predrawn medication syringes collected for culture were ketamine, midazolam, fentanyl, thiopentone, rocuronium, suxamethonium, metaraminol and normal saline. The samples were incubated and cultured at a tertiary hospital pathology laboratory using best-practice methodology for non-tissue samples. The samples were collected from June 2017 to February 2018.
Results: The mean dwell times ranged from 30.7 hours (fentanyl at HRS) to 48.5 hours (rocuronium at CFS). None of the 299 cultured samples yielded significant micro-organisms. One sample of suxamethonium with a syringe dwell time of 34 hours grew but was likely a contaminant introduced during sample collection.
Conclusion: Predrawing of the eight studied medications for urgent prehospital procedures appears to be a microbiologically safe practice with syringe dwell times up to 48 hours.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/emermed-2018-207864 | DOI Listing |
J Hosp Infect
March 2024
Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN, USA. Electronic address:
Background: A recent study confirmed significant contamination of syringe tips following routine anaesthesia practice of at least 6 h in duration.
Aim: We assessed the relative efficacy of clinically relevant syringe tip disinfection techniques following contamination with the hyper transmissible and more pathogenic Staphylococcus aureus sequence type 5 (S. aureus ST5) strain characteristic associated with increased strength of biofilm formation and greater desiccation tolerance.
BMJ Qual Saf
January 2023
Institute of Intensive Care Medicine, University Hospital Zurich, Zurich, Switzerland
Background: Patients in intensive care units are prone to the occurrence of medication errors. Look-alike, sound-alike drugs with similar drug names can lead to medication errors and therefore endanger patient safety. Capitalisation of distinct text parts in drug names might facilitate differentiation of medication labels.
View Article and Find Full Text PDFLancet Infect Dis
July 2021
Service des Urgences et SAMU 86 Centre 15, CHU de Poitiers, France; Université de Poitiers, UFR de Médecine-Pharmacie, Poitiers, France; INSERM U1070, Pharmacologie des Agents Anti-Infectieux, Poitiers, France. Electronic address:
Background: Two billion peripheral venous catheters are sold globally each year, but the optimal skin disinfection and types of devices are not well established. We aimed to show the superiority of disinfection with 2% chlorhexidine plus alcohol over 5% povidone iodine plus alcohol in preventing infectious complications, and of closed integrated catheters, positive displacement needleless-connectors, disinfecting caps, and single-use prefilled flush syringes used in combination (innovation group) over open catheters and three-way stopcocks for treatment administration (standard group) in preventing catheter failure.
Methods: We did an open-label, randomised-controlled trial with a two-by-two factorial design, for which we enrolled adults (age ≥18 years) visiting the emergency department at the Poitiers University Hospital, France, and requiring one peripheral venous catheter before admission to the medical wards.
Eur Endocrinol
April 2020
Department of Endocrinology, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh.
Introduction: Diabetes mellitus is highly prevalent in Bangladesh and insulin is often needed for diabetes control. We lack sufficient data on the insulin injection technique and injection-related complications.
Methods: The Bangladesh Insulin Injection Technique Survey (BIITS) was conducted in 2018 in 18 centres throughout Bangladesh, involving 847 patients taking insulin for at least 6 months.
J Racial Ethn Health Disparities
October 2020
David and Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA.
Objectives: Non-Hispanic Blacks (NHB) and Hispanic/Latinos (H/L) are affected disproportionately by type 2 diabetes (T2DM) and its complications due to a myriad of reasons. Lack of diabetes education has been identified as one risk factor for poorly controlled diabetes. For persons using insulin, poor insulin administration technique can be problematic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!