Purpose: To correlate the dose response and changes in microscopic structures of the radiochromic films exposed to the clinical magnetic field in the range 1.5-3 T with standard and flattening filter-free (FFF) photon beams.

Methods: The radiochromic film was cut into 5 × 5 cm sheets/samples from one batch. These samples were exposed to a 1.5-T and/or 3-T B-fields from an MRI scanner using an abdominal sequence for 7 min before and after irradiation with 6 MV and/or 6 MV FFF beams. Films were placed in a reference condition at 5 cm depth in a solid water phantom and exposed up to 20 Gy. The sample orientation was maintained the same during exposure, readout, and scanning electron microscopic (SEM) analysis. The samples were scanned with an Epson Expression 11000XL in a 48-bit RGB color mode at 300 dpi with red channel. Scanned images were processed in Image J and red channel mean intensity values were recorded. The samples were then coated with 6 nm gold and imaged by SEM Teneo (5 kV, 13 pA) under 2000, 2500, and 3000 magnifications for texture analysis.

Results: The changes in the microstructure of the films in magnetic fields (1.5- and 3.0-T) were dose dependent. The orientation and granular size of samples at higher doses were altered compared to the controls. Needle-shaped structures of the active layer were longer and aligned for samples exposed to higher doses and magnetic field. However, no significant changes in optical density due to the presence of a magnetic field pre/postirradiation up to 20 Gy were observed.

Conclusion: Fine structures of the film represent the polymerization characteristics that are affected by the radiation dose in the magnetic field. Upon exposure to radiation, diacetylene monomers undergo polymerization that forms longer chains with a temporal response. Even though this study did not notice any significant changes in optical density due to the presence of magnetic field, this should be studied in simultaneous application of the magnetic field during treatment in a dedicated MR-linac unit.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13248DOI Listing

Publication Analysis

Top Keywords

magnetic field
28
radiochromic films
8
magnetic
8
films magnetic
8
samples exposed
8
red channel
8
higher doses
8
changes optical
8
optical density
8
density presence
8

Similar Publications

Magnetic field-oriented conductive decellularized extracellular matrix hydrogel synergizes with electrical stimulation to promote spinal cord injury repair and electrophysiological function restoration.

Biomater Adv

December 2024

Key Laboratory for Ultrafine Materials of Ministry of Education, Frontiers Science Center for Materiobiology and Dynamic Chemistry, Engineering Research Center of Biomedical Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237, PR China. Electronic address:

Spinal cord injury (SCI) results in electrophysiological and behavioral dysfunction. Electrical stimulation (ES) is considered to be an effective treatment for mild SCI; however, ES is not applicable to severe SCI due to the disruption of electrical conduction caused by tissue defects. Therefore, the use of conductive materials to fill the defects and restore electrical conduction in the spinal cord is a promising therapeutic strategy.

View Article and Find Full Text PDF

The present work describes the process of the creation and analysis of the first dataset containing processing parameters and functional properties of soft magnetic composites (SMC). All data were obtained experimentally using Fe-3% MgO system. When creating samples, parameters such as a size of MgO nanoparticles, pressing pressure, sintering temperature, time and atmosphere were varied.

View Article and Find Full Text PDF

High thermoelectric performance is generally achieved by synergistically optimizing two or even three of the contradictorily coupled thermoelectric parameters. Here we demonstrate magneto-thermoelectric correlation as a strategy to achieve simultaneous gain in an enhanced Seebeck coefficient and reduced thermal conductivity in topological materials. We report a large magneto-Seebeck effect and high magneto-thermoelectric figure of merit of 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!