The present review casts a critical eye on intraocular pressure (IOP) monitoring and its value in current and future glaucoma care. Crucially, IOP is not fixed, but varies considerably during the 24-h cycle and between one visit and another. Consequently, a single IOP measurement during so-called office hours is insufficient to characterize the real IOP pathology of a patient with glaucoma. To date IOP remains the principal and only modifiable risk factor for the development and progression of glaucoma. Only by evaluating IOP characteristics (mean, peak and fluctuation of IOP) at diagnosis and after IOP-lowering interventions can we appreciate the true efficacy of therapy. Unfortunately, a major limiting factor in glaucoma management is lack of robust IOP data collection. Treatment decisions, advancement of therapy and even surgery are often reached on the basis of limited IOP evidence. Clearly, there is much room to enhance our decision-making and to develop new algorithms for everyday practice. The precise way in which daytime IOP readings can be used as predictors of night-time or 24-h IOP characteristics remains to be determined. In practice it is important to identify those at-risk glaucoma patients for whom a complete 24-h curve is necessary and to distinguish them from those for whom a daytime curve consisting of three IOP measurements (at 10:00, 14:00 and 18:00) would suffice. By employing a staged approach in determining the amount of IOP evidence needed and the rigour required for our monitoring approach for the individual patient, our decisions will be based on more comprehensive data, while at the same time this will optimize use of resources. The patient's clinical picture should be the main factor that determines which method of IOP monitoring is most appropriate. A diurnal or ideally a 24-h IOP curve will positively impact the management of glaucoma patients who show functional/anatomical progression, despite an apparently acceptable IOP in the clinic. The potential impact of nocturnal IOP elevation remains poorly investigated. The ideal solution in the future is the development of non-invasive methods for obtaining continuous, Goldmann equivalent IOP data on all patients prior to key treatment decisions. Moreover, an important area of future research is to establish the precise relationship between 24-h IOP characteristics and glaucoma progression.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6223998PMC
http://dx.doi.org/10.1007/s12325-018-0812-zDOI Listing

Publication Analysis

Top Keywords

iop
19
iop characteristics
12
24-h iop
12
glaucoma
8
iop monitoring
8
iop data
8
treatment decisions
8
iop evidence
8
glaucoma patients
8
24-h
5

Similar Publications

Purpose: To assess the efficacy and safety of PreserFlo MicroShunt (PMS) combined with mitomycin C in patients with medically treated primary open-angle glaucoma (POAG).

Study Design: A retrospective observational study.

Methods: The study examined 83 eyes from 83 patients with medically treated glaucoma surgery naive POAG.

View Article and Find Full Text PDF

Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.

Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.

View Article and Find Full Text PDF

Predictors of anterior chamber angle status at the time of neovascular glaucoma diagnosis.

Am J Ophthalmol Case Rep

December 2024

Department of Ophthalmology and Visual Science, University of Chicago Medical Center, Chicago, IL, USA.

Purpose: To identify clinical features which may predict the angle status of a large cohort of NVG eyes at the time of diagnosis.

Observations: Chart review was performed for all NVG eyes from 2010 to 2022. Complete angle closure was defined as having >75 % PAS, partial angle closure as having 1-75 % PAS, and open angles as having 0 % PAS.

View Article and Find Full Text PDF

Large-scale quantum networks require dynamic and resource-efficient solutions to reduce system complexity with maintained security and performance to support growing number of users over large distances. Current encoding schemes including time-bin, polarization, and orbital angular momentum, suffer from the lack of reconfigurability and thus scalability issues. Here, we demonstrate the first-time implementation of frequency-bin-encoded entanglement-based quantum key distribution and a reconfigurable distribution of entanglement using frequency-bin encoding.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the correlation between axial length (AL) and retinal oxygen dynamic parameters in adult patients.

Methods: This was an observational cross-sectional study with 79 Chinese adults with myopia aged 18 to 37 years. All participants underwent AL measurements, cycloplegic refraction, and other ophthalmic examinations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!