A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characterization and vascularization of a 3D-printed hydroxyapatite scaffold with different extracellular matrix coatings under perfusion culture. | LitMetric

For the fabrication of appropriate bone tissue-engineered constructs several prerequisites should be fulfilled. They should offer long-term stability, allow proper cell attachment and proliferation and furthermore be osteoinductive and easy to be vascularized. Having these requirements as background, we fabricated a novel porous 3D-printed hydroxyapatite (HA) scaffold and treated it with oxygen plasma (OPT). MG-63 pre-osteoblast-seeded bone constructs allowed good cell attachment and proliferation, which was even better when cultivated in a perfusion flow bioreactor. Moreover, the deposition of extracellular matrix (ECM) on the otherwise inorganic surface changed the mechanical properties in a favourable manner: elasticity increased from 42.95±1.09 to 91.9±5.1 MPa (assessed by nanoindentation). Compared to static conditions, osteogenic differentiation was enhanced in the bioreactor, with upregulation of ALP, collagen I and osteocalcin gene expression. In parallel experiments, primary human bone marrow mesenchymal stromal cells (hBMSCs) were used and findings under dynamic conditions were similar; with a higher commitment towards osteoblasts compared to static conditions. In addition, angiogenic markers CD31, eNOS and VEGF were upregulated, especially when osteogenic medium was used rather than proliferative medium. To compare differently fabricated ECMs in terms of vascularization, decellularized constructs were tested in the chorioallantoic membrane (CAM) assay with subsequent assessment of the functional perfusion capacity by MRI in the living chick embryo. Here, vascularization induced by ECM from osteogenic medium led to a vessel distribution more homogenous throughout the construct, while ECM from proliferative medium enhanced vessel density at the interface and, to a lower extent, at the middle and top. We conclude that dynamic cultivation of a novel porous OPT HA scaffold with hBMSCs in osteogenic medium and subsequent decellularization provides a promising off-the-shelf bone tissue-engineered construct.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6310875PMC
http://dx.doi.org/10.1242/bio.034488DOI Listing

Publication Analysis

Top Keywords

osteogenic medium
12
3d-printed hydroxyapatite
8
hydroxyapatite scaffold
8
extracellular matrix
8
bone tissue-engineered
8
cell attachment
8
attachment proliferation
8
novel porous
8
compared static
8
static conditions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!