A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Data on spot-kits versus titration method for iodine determination in salt: Performance and validity. | LitMetric

The aim of this data is comparison of achieved data from salt iodine measurement by titration method with using sodium thiosulfate in presence of lugol׳s reagent and commercial spot- kit. Titration measurement was carried out in two different laboratories using standard samples. 437 samples including 20 commercial brands were collected throughout Iran. The iodine contents of the samples were measured by both the titration method and two most frequently used spot-kit brands in Iran. There is no significant differences between the results obtained from the two brands of spot-kits (ICC = 0.797). The kits sensitivity for determination of negative samples was high (more than 0.9) but by increasing the iodine concentration up to 15 ppm, the kits' sensitivity was decreased. These findings indicate that the titration method is necessary for quantitative purposes, especially for concentrations higher than 30 ppm. However, spot-kits are suitable for qualitative and semi-quantitative measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187014PMC
http://dx.doi.org/10.1016/j.dib.2018.10.001DOI Listing

Publication Analysis

Top Keywords

titration method
16
titration
5
data spot-kits
4
spot-kits versus
4
versus titration
4
method
4
iodine
4
method iodine
4
iodine determination
4
determination salt
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!