A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Effect of the Use of Different Types of Cement and Zirconium Post Systems on Endondontically Treated Teeth. | LitMetric

Background: Prefabricated zirconium upgrading systems were examined to satisfy aesthetic needs in endodontically treated teeth. Endodontically treated teeth, together with non-metallic posts and superstructure, are substructures that enable the production of prosthetic structures that will allow aesthetics, resulting from normal light transmission. To investigate and analyse the retention of zirconium post systems cemented with RelyX Unicem 2 Automix (RLX) cement with Pull-out test.

Aim: To examine the retention of zirconium post systems, cemented with Multi-Link Automix (MLA) cement and RelyX Unicem 2 Automix (RLX) cement with Pull-out test.

Material And Methods: In this study were used, 120 post systems of the company ZIRIX NORDIN - Switzerland, with different diameters d1 = 1.2, were used: d2 = 1.35, d3 = 1.5, and two types of resin cements: Multilink Automix-Ivoclar (MLA), and RelyX Unicem 2 Automix (RLX) - 3 M ESPE.

Results: The analysis of the extraction force in newtons (N) zirconium post systems of Multilink Automix cement according to subgroups of three diameters is consequently 481.3 ± 1.9 vs 462.9 ± 4.5 vs 454.2 ± 2.2. The analysis of the extraction strength in the newtons (N) zirconium post systems of RelyX Unicem 2 Automix cement in the entire sample is 577.9 ± 6.1 N.

Conclusion: The largest diameter of the posts significantly increases the resistance of fractures compared to the smaller two diameters used in the experimental study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6182529PMC
http://dx.doi.org/10.3889/oamjms.2018.326DOI Listing

Publication Analysis

Top Keywords

post systems
24
zirconium post
20
relyx unicem
16
unicem automix
16
treated teeth
12
automix rlx
12
endodontically treated
8
retention zirconium
8
systems cemented
8
rlx cement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!