Aim Of The Study: The aim of this study is to assess the prevalence and evolution of perirenal fluid collections in a group of 488 patients who have undergone kidney transplantation.

Material And Methods: Sonographic documentation of 488 deceased-donor kidney recipients was evaluated for the prevalence of perirenal fluid collections and their evolution in time, depending on selected demographic features of the patients, time of detection, initial dimensions and precise position of the collection relative to the kidney and the location of the transplanted organ in the right or left iliac fossa. The collected data were used for statistical analysis to determine the strength of the potential relationships.

Results: In 146 out of 488 subjects perirenal fluid collections were found. In 1/3 of the patients more than one fluid collection was diagnosed. Over 40% of fluid collections were detected within 10 days from the date of the first scan and 24.11% were detected within 10-20 days from the date of the first scan. The majority of fluid collections were located near the lower pole of the kidney. Perihilar collections were the least common. Collections encapsulating the kidney and subcutaneous collections were the largest in size on average. A statistically significant difference between the size of collections located on the surface and the size of those located near the upper pole of the transplanted kidney was demonstrated. However, no correlation was proven to exist between the persistence of the fluid collection and its position relative to the transplanted kidney and its initial size.

Conclusions: The correct evaluation of a fluid collection's dynamics of development and nature requires periodic follow-up of the recipient, preferably in a single clinical center. Ultrasonography is an inexpensive, non-invasive and repeatable method for the determination of the presence of fluid collections. However, the decision whether treatment is necessary requires the sonographic image to be compared with the laboratory signs of inflammation and biochemical analysis of the contents of fluid collections.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6440513PMC
http://dx.doi.org/10.15557/JoU.2018.0018DOI Listing

Publication Analysis

Top Keywords

fluid collections
32
collections
12
perirenal fluid
12
fluid
11
prevalence evolution
8
kidney
8
aim study
8
fluid collection
8
days scan
8
collections located
8

Similar Publications

Accuracy and clinical applicability of plasma tau 181 and 217 for Alzheimer's disease diagnosis in a memory clinic cohort.

J Neurol

January 2025

Alzheimer's Disease and Other Cognitive Disorders Unit, Neurology Service, Hospital Clínic de Barcelona, Fundació de Recerca Clínic - Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Universitat de Barcelona, Villaroel 170, 08036, Barcelona, Spain.

Plasma tau phosphorylated at threonine 181 (p-tau181) and 217 (p-tau217) have demonstrated high accuracy for Alzheimer's disease (AD) diagnosis, defined by CSF/PET amyloid beta (Aβ) positivity, but most studies have been performed in research cohorts, limiting their generalizability. We studied plasma p-tau217 and p-tau181 for CSF Aβ status discrimination in a cohort of consecutive patients attending an academic memory clinic in Spain (July 2019-June 2024). All patients had CSF AD biomarkers performed as part of their routine clinical assessment.

View Article and Find Full Text PDF

Background And Aims: Pancreatic fluid collections (PFCs), including walled-off necrosis (WON), are significant complications of acute pancreatitis, and their management often involves drainage, although the optimal type of stent for this purpose remains uncertain. This meta-analysis aimed to compare metal versus plastic stents for endoscopic ultrasound (EUS)-guided drainage of PFCs.

Methods: We searched PubMed, Embase, and Cochrane Library for randomized controlled trials (RCTs) comparing metal with plastic stents for drainage of PFCs.

View Article and Find Full Text PDF

Aim: To evaluate the impact of fluid volume fluctuations quantified with artificial intelligence in optical coherence tomography scans during the maintenance phase and visual outcomes at 12 and 24 months in a real-world, multicentre, national cohort of treatment-naïve neovascular age-related macular degeneration (nAMD) eyes.

Methods: Demographics, visual acuity (VA) and number of injections were collected using the Fight Retinal Blindness tool. Intraretinal fluid (IRF), subretinal fluid (SRF), pigment epithelial detachment (PED), total fluid (TF) and central subfield thickness (CST) were quantified using the RetinAI Discovery tool.

View Article and Find Full Text PDF

Background: New diagnostic tools have emerged to assist the traditional diagnosis of malignant pleural effusion (MPE), such as high fluorescence cells (HFc) and tumor markers (TMs), determined by clinical laboratory automated pleural fluid workup. This study aimed to evaluate the diagnostic ability of the combination of HFc and TMs for diagnosing MPE.

Methods: We recruited hospitalized patients with pleural effusion at Parc Taulí University Hospital.

View Article and Find Full Text PDF

Protocol for correlating the gut microbiome and metabolomics in patients with intracranial aneurysms.

STAR Protoc

January 2025

Brain Research Center, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan 430071, China; Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan 430071, China; Frontier Science Center for Immunology and Metabolism, Wuhan University, Wuhan 430072, China; Medical Research Institute, Wuhan University, Wuhan 430072, China; Sino-Italian Ascula Brain Science Joint Laboratory, Wuhan University, Wuhan 430071, China. Electronic address:

Gut-microbiome-combined metabolomics studies in cerebrovascular disease highlight the microbiota-gut-brain axis in neurological disorders. Here, we present a protocol for correlating the gut microbiome and metabolomics in patients with intracranial aneurysms. We describe steps for sample collection, fecal genomic DNA extraction, rRNA PCR amplification, sequencing library construction, and rRNA sequencing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!