Background: In theory, temporary posterior atlantoaxial screw-rod fixation for type II odontoid fractures is a way to preserve rotatory motion. However, the healing rate of type II odontoid fractures treated in this way is unknown; that is, the risk associated with conducting a temporary screw-rod fixation for type II odontoid fractures is unknown. This study investigates the healing rate of type II odontoid fractures treated with posterior atlantoaxial screw-rod fixation by CT imaging and evaluates the feasibility of conducting a temporary screw-rod fixation for type II odontoid fractures.

Methods: Patients with type II odontoid fracture who underwent posterior atlantoaxial screw-rod fixation in our spine center from January 2011 to December 2014 were identified. Patients older than 65 years or younger than 18 years were excluded. Those who were confirmed to have healing odontoid fractures on CT imaging were included. Those in whom fracture healing was not confirmed were asked to undergo a CT examination. Fracture healing was confirmed on the basis of the presence of bridging bone across the odontoid fracture site on CT imaging.

Results: Seventy-seven patients (56 men and 21 women) were included in the study. The average age of the patients was 40.7 ± 11.6 years (range, 18 to 64 years). The mean duration of follow-up was 26.4 ± 4.6 months (range, 24 to 40 months). Fracture healing was observed in 73 patients (94.8%).

Discussion: The healing rate of type II odontoid fractures (with an age range of 18 to 64 years) treated with modern posterior atlantoaxial fixation is relatively high. For patients at that age range, posterior atlantoaxial temporary screw-rod fixation for type II odontoid fractures can be conducted with a low risk of nonunion.

Level Of Evidence: Level IV, therapeutic.

Download full-text PDF

Source
http://dx.doi.org/10.5435/JAAOS-D-17-00277DOI Listing

Publication Analysis

Top Keywords

type odontoid
36
odontoid fractures
32
screw-rod fixation
28
posterior atlantoaxial
24
healing rate
16
rate type
16
atlantoaxial screw-rod
16
fixation type
16
fractures treated
12
temporary screw-rod
12

Similar Publications

Autosomal recessive hypophosphatemic rickets type 2 (ARHR2) is an uncommon hereditary form of rickets characterised by chronic renal phosphate loss and impaired bone mineralisation. This results from compound heterozygous or homozygous pathogenic variants in ectonucleotide pyrophosphatase/phosphodiesterase 1 (ENPP1), a key producer of extracellular inorganic pyrophosphate (PPi) and an inhibitor of fibroblast growth factor23 (FGF23). ENPP1 deficiency impacts FGF23 and increases its activity.

View Article and Find Full Text PDF

Atalanto-occipital dislocations with type II fractures of the odontoid process are rare, reporting 7 cases for every 784 upper cervical spine injuries, an incidence of <0.3% and are related to a high rate of morbidity and mortality. Regarding C2 fractures, the most common are in the odontoid process, representing 7%, classified by Anderson and D'Alonso according to their level, with the highest rate of pseudarthrosis in zone II of up to 85% are caused mainly by car accidents.

View Article and Find Full Text PDF

Instrumentation of the cervical spine particularly at the higher cervical levels like C2 presents unique challenges mainly because of their complex anatomy and proximity to neurovascular structures. The goal of the article is to demonstrate that using navigation technologies in inserting anterior odontoid screws can enhance the precision and safety of surgery. We describe a novel approach for anterior C2 odontoid fixation using a three-pin radiolucent Mayfield clamp with intra-operative CT registration and cranial brainlab navigation.

View Article and Find Full Text PDF

Robot-assisted anterior odontoid screw for the treatment of type Ⅱ odontoid fractures: Safety and effectiveness analysis.

Clin Neurol Neurosurg

December 2024

Department of Spine, Baoji City Hospital of Traditional Chinese Medicine, Baoji, Shaanxi Province, People's Republic of China. Electronic address:

Background: Anterior odontoid screw fixation is considered to be preferred surgical treatment for the type Ⅱ odontoid fractures. However, due to the high difficulty to insert odontoid screw with barehand, the high risk of screw misalignment and damage to surrounding important tissue structures, we urgently need robot-assisted screw insert navigation technology to improve the safety and accuracy of inserting odontoid screws.

Methods: We retrospectively analyzed 7 patients with type II odontoid fractures who underwent Tinavi robot-assisted screw insert technology from May 2018 to May 2019 at our hospital.

View Article and Find Full Text PDF

Introduction And Importance: Odontoid fractures of the second cervical vertebra (C2) are categorized into three types, with type III extending into the body of the axis. These fractures, often resulting from high-energy trauma, can cause significant instability and neurological issues. This case report discusses a 43-year-old male with a type III odontoid fracture and C1-C2 fracture dislocation, demonstrating the effectiveness of traditional neurosurgical techniques in managing such complex injuries.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!