Quantitative Lateral Flow Strip Sensor Using Highly Doped Upconversion Nanoparticles.

Anal Chem

Institute for Biomedical Materials and Devices, Faculty of Science , University of Technology Sydney, Sydney , New South Wales 2007 , Australia.

Published: November 2018

AI Article Synopsis

  • Paper-based lateral flow assays are cost-effective for quick diagnostics but lack sensitivity for detecting early-stage cancer biomarkers.
  • A new compact device utilizes high-powered illumination and specially designed upconversion nanoparticles to significantly enhance detection brightness.
  • This innovative approach achieved record low detection limits for specific cancer biomarkers, indicating potential for more accurate early diagnosis.

Article Abstract

Paper-based lateral flow assays, though being low-cost and widely used for rapid in vitro diagnostics, are indicative and do not provide sufficient sensitivity for the detection and quantification of low abundant biomarkers for early stage cancer diagnosis. Here, we design a compact device to create a focused illumination spot with high irradiance, which activates a range of highly doped 50 nm upconversion nanoparticles (UCNPs) to produce orders of magnitude brighter emissions. The device employs a very low-cost laser diode, simplified excitation, and collection optics and permits a mobile phone camera to record the results. Using highly erbium ion (Er)-doped and thulium ion (Tm)-doped UCNPs as two independent reporters on two-color lateral flow strips, new records of limit of detection (LOD), 89 and 400 pg/mL, have been achieved for the ultrasensitive detection of prostate specific antigen (PSA) and ephrin type-A receptor 2 (EphA2) biomarkers, respectively, without crosstalk. The technique and device presented in this work suggests a broad scope of low-cost, rapid, and quantitative lateral flow assays in early detection of bioanalytes.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.8b04330DOI Listing

Publication Analysis

Top Keywords

lateral flow
16
quantitative lateral
8
highly doped
8
doped upconversion
8
upconversion nanoparticles
8
flow assays
8
low-cost rapid
8
flow
4
flow strip
4
strip sensor
4

Similar Publications

Solitary foraging insects like desert ants rely heavily on vision for navigation. While ants can learn visual scenes, it is unclear what cues they use to decide if a scene is worth exploring at the first place. To investigate this, we recorded the motor behavior of Cataglyphis velox ants navigating in a virtual reality set-up (VR) and measured their lateral oscillations in response to various unfamiliar visual scenes under both closed-loop and open-loop conditions.

View Article and Find Full Text PDF

Aptamer-Antibody Birecognized Sandwich SERRS Biosensor in Accurate and Rapid Identification of Intraoperative Parathyroid Hormone.

Anal Chem

January 2025

State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, Discipline of Intelligent Instrument and Equipment, Cancer Center and Department of Breast and Thyroid Surgery, Department of Ultrasound, Xiang'an Hospital of Xiamen University, School of Medicine, Laboratory Animal Center Xiamen University, Xiamen University, Xiamen 361005, China.

With the increasing incidence of thyroid cancer worldwide and the increasing demand for surgery, the risk of parathyroid injury is also increasing, which will lead to postoperative hypoparathyroidism (HP) and hypocalcemia. In order to improve the quality of life of patients after surgery, there is an urgent need to develop a novel platform that can identify the parathyroid gland immediately during surgery. The parathyroid gland promotes the increase of blood calcium concentration by secreting parathyroid hormone (PTH).

View Article and Find Full Text PDF

The incidence of cervical cancer continues to rise in underdeveloped regions due to low human papillomavirus (HPV) vaccination rates and inadequate screening systems. To achieve convenient, rapid, and accurate detection of HPV, we developed a three-wire lateral flow strip assay system based on dual-OR logic gates for rapid and simultaneous detection of HPV subtypes 16 and 18 in a single test. The system combines three-branch-catalytic hairpin assembly (TCHA)-mediated signal amplification with simple OR logic gate-based signal output to improve detection rates while enabling HPV 16/18 subtype identification.

View Article and Find Full Text PDF

Objective: The study aims to develop continuous trajectory profiles along curves with minimal error. It also focuses on formulating a percentage trajectory transection rate model as a function of geometric parameters (e.g.

View Article and Find Full Text PDF

Background: Dengue fever (DF) poses a growing global threat, necessitating a comprehensive one-health approach to address its complex interplay between human, animal, and environmental factors. In Oyo State, Nigeria, the true burden of DF remains unknown due to underdiagnosis and misdiagnosis as malaria, exacerbated by poor health-seeking behavior, weak surveillance systems, and inadequate health infrastructure. Adopting a one-health approach is crucial to understanding the dynamics of DF transmission.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!