Objective: To determine the relationships between intraoperative hemodynamic parameters and delayed hemodynamic recovery after valve deployment and identify the predictive factors of delayed hemodynamic recovery by focusing on intraoperative hemodynamics in patients with transcatheter aortic valve replacement (TAVR).

Design: A retrospective study.

Setting: A single university hospital.

Participants: Sixty-four patients who underwent elective TAVR between 2015 and 2017.

Interventions: No intervention.

Measurements And Main Results: The 64 patients were divided into the following 2 groups according to the time for recovery: systolic arterial pressure exceeded 90 mmHg and central venous oxygen saturation (ScvO) exceeded 65%-delayed recovery (DR) (n = 36) group, and early recovery (ER) (n = 28) group. ScvO in the DR group was not lower than that in the ER group after induction of anesthesia. However, ScvO in the DR group gradually decreased and was lower than that in the ER group before valve deployment, despite improvement in blood pressure through the administration of vasopressor agents.

Conclusion: ScvO monitoring during TAVR is useful to predict delayed recovery greater than 60 seconds after valve deployment in TAVR.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2018.08.186DOI Listing

Publication Analysis

Top Keywords

valve deployment
16
delayed hemodynamic
12
hemodynamic recovery
12
relationships intraoperative
8
intraoperative hemodynamic
8
hemodynamic parameters
8
parameters delayed
8
recovery valve
8
transcatheter aortic
8
aortic valve
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!