Study Design: Retrospective study.

Purpose: To evaluate radiological parameters as indicators for posterior ligamentous complex (PLC) injuries in the case of limited availability of magnetic resonance imaging.

Overview Of Literature: Traumatic thoracolumbar spinal fractures with PLC injuries can be misdiagnosed on X-rays or computed tomography scans. This study aimed to retrospectively assess unrecognized PLC injuries and evaluate radiographic parameters as indicators of PLC injuries requiring surgery.

Methods: In total, 314 patients with type A and type B2 fractures who underwent surgical treatment between 2001 and 2010 were included. The frequency of misdiagnosis was reassessed, and radiographic parameters were evaluated and correlated.

Results: The average age of the patients was 51.8 years. There were 225 type A3/A4 and 89 type B2 fractures; 39 of the type B2 fractures (43.8%) had been misdiagnosed as type A fractures. Type B fractures presented with a significantly higher kyphotic wedge angle and Cobb angle and a lower sagittal index (SI) than type A fractures. In addition, the normalized interspinous distance was higher in type B2 fractures. The significant mathematical indicators for PLC injuries were as follows: Cobb angle+kyphotic wedge angle >29°; Cobb angle2 >170°; and vertebral angle/SI >25.

Conclusions: The results demonstrated that PLC injuries are frequently misdiagnosed. Correlations between certain radiological parameters associated with PLC injuries can be useful indicators of the presence of such injuries requiring surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6365780PMC
http://dx.doi.org/10.31616/asj.2017.0333DOI Listing

Publication Analysis

Top Keywords

plc injuries
28
type fractures
28
injuries
9
type
9
posterior ligamentous
8
ligamentous complex
8
radiological parameters
8
parameters indicators
8
fractures
8
radiographic parameters
8

Similar Publications

SN514 is a thermolysin-like enzyme under development as a debrider. Preclinical and non-clinical studies supported a first in human healthy volunteer study to predict the need for protection of periwound skin. Pharmacologic activity testing compared digestion of collagen, fibrin, and elastin with relevant enzymes.

View Article and Find Full Text PDF

Objectives: This study aimed to introduce a new arthroscopic method for reconstructing the popliteus tendon (PT). This minimally invasive technique is performed through the posterolateral corner (PLC) of the knee, which can reconstruct the posterolateral rotary instability (PLRI) of the knee.

Methods: Thirty-nine patients (8 females, 31 males) with PLC injury and normal knee alignment underwent arthroscopic PT reconstruction.

View Article and Find Full Text PDF

Thoracolumbar fractures: Factors predicting failure of percutaneous short- and long-segment posterior fixation.

Brain Spine

December 2024

Orthopedic Surgery Department, Unidade Local de Saúde de Braga, Portugal - Sete Fontes, São Victor, 4710-243, Braga, Portugal.

Introduction: Thoracolumbar (TL) transition trauma is frequent and challenging. Although short- (SSPF) and long-segment posterior fixation (LSPF) are its mainstay treatment, little is known about their failure rates and reasons behind it.

Research Question: understand why TL instrumentations fail and what factors influence it.

View Article and Find Full Text PDF

Introduction: Fibular- and tibiofibular-based reconstructions are the gold standard treatment for posterolateral corner (PLC) injuries of the knee. This is the first report describing a wholly tibial-based PLC reconstruction.

Case Report: A 50-year-old female presented with knee instability following proximal fibular resection for a benign tumor, associated with chronic anterior cruciate ligament (ACL) deficiency from a previous injury.

View Article and Find Full Text PDF

Development of an Equivalent Analysis Model of PVB Laminated Glass for TRAM Crash Safety Analysis.

Polymers (Basel)

December 2024

Department of Mechanical Engineering, Hanyang University ERICA, 55, Hanyangdaehak-ro, Sangnok-gu, Ansan-si 15588, Gyeonggi-do, Republic of Korea.

This study focuses on an equivalent model of Polyvinyl Butyral (PVB) laminated glass to simulate the Head Injury Criterion (HIC) when a pedestrian collides with a TRAM. To simulate the collision behavior that occurs when a pedestrian's head collides with PVB laminated glass, a comparison was made between the results of the widely used PLC model for PVB laminated glass modeling and an actual dynamic head impact test. The material properties of the tempered glass and PVB film used in the PLC and equivalent models were obtained via four-point bending tests and tensile tests, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!