A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability and validity of various laboratory methods of body composition assessment in young adults. | LitMetric

Accurate measures of body composition (BC) are essential for performance and health. In addition to accuracy, BC measures should be practical and be minimally invasive to maximize their utility. The purpose of the present study was to compare the day-to-day variability and validity of four common laboratory-based body composition assessments to a criterion four-compartment model. Dual x-ray absorptiometry (DXA), air displacement plethysmography (BP), multi-frequency bioelectrical impedance (MF-BIA) and underwater weighing (UWW) were performed twice in a sample of 32 young men and women. Participants were assessed in a fasted, euhydrated state 2-7 days apart. All methods were compared to a criterion four-compartment model using BP-derived body volume, DXA-derived bone mineral content and MF-BIA-derived total body water (4C ). Additional four-compartment models using UWW- and DXA-derived body volume were also examined (4C ) and (4C ). Validity results were conducted with paired t-tests and Bland-Altman analysis. Reliability was determined using intraclass correlations (ICC), coefficients of variation (CV) and standard error of the measurement (SEM). Validity analysis revealed that all methods overestimated per cent body fat and fat mass, and underestimated fat-free mass when compared with 4C , but only DXA and BP were significantly different (P<0·008). All measures were highly reliable across days (ICCs > 0·9, CVs < 12%). Results of the present study indicate that typical laboratory-based methods of body composition are valid and reliable. However, we caution that results should not be translated between methods and assessments should be performed with the same instrument when the goal is to monitor changes in body composition over time.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cpf.12550DOI Listing

Publication Analysis

Top Keywords

body composition
12
criterion four-compartment
8
four-compartment model
8
body volume
8
body
7
reliability validity
4
validity laboratory
4
laboratory methods
4
methods body
4
composition assessment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!