A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Silver-filled MWCNT nanocomposite as a sensing element for voltammetric determination of sulfamethoxazole. | LitMetric

Silver-filled MWCNT nanocomposite as a sensing element for voltammetric determination of sulfamethoxazole.

Anal Chim Acta

Department of Analytical Chemistry, Lorestan University, 68137-17133, Khorramabad, Iran.

Published: December 2018

Here, we introduce a new electrode based on Silver-filled multi-walled carbon nanotube (Ag-MWCNT) and methyltrioctyl ammonium chloride (MTOAC) for highly sensitive voltammetric measurement of Sulfamethoxazole (SMX). The electrode showed an electrocatalytic activity as it led to the diminution of the overpotential and an increase in peak current for SMX oxidation in a phosphate buffer solution (pH 6.0). Analysis of surface topography and electrochemical properties of the modified electrode was examined by TEM, EDX and EIS, respectively. Electrochemical performance of the modified electrode was investigated with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques for determination of SMX in aqueous solution. In addition, the oxidation process was found to be dependent on the pH of the buffer solution. Under optimal conditions, a linear relationship between the oxidation current and SMX concentration was found in a range 0.05-70 μM (R = 0.997) with a detection limit of 0.01 μM after 2 min of accumulating time. The electrode was successfully used to quantify SMX in pharmaceutical formulations and human urine by DPV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2018.07.061DOI Listing

Publication Analysis

Top Keywords

current smx
8
buffer solution
8
modified electrode
8
electrode
5
smx
5
silver-filled mwcnt
4
mwcnt nanocomposite
4
nanocomposite sensing
4
sensing element
4
element voltammetric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!