Upconversion Nanoparticles (UCNPs) enable direct measurement of the local temperature with high temporal and thermal resolution and sensitivity. Current studies focusing on small animals and cellular systems, based on continuous wave (CW) infrared excitation sources, typically lead to localized thermal heating. However, the effects of upconversion bioimaging at the molecular scale, where higher infrared intensities under a tightly focused excitation beam, coupled with pulsed excitation to provide higher peak powers, is not well understood. We report on the feasibility of 800 and 980 nm excited UCNPs in thermal sensing under pulsed excitation. The UCNPs report temperature ratiometrically with sensitivities in the 1 × 10 K range under both excitation wavelengths. Our optical measurements show a ln(I/I) vs. 1/T dependence for both 800 nm and 980 nm excitations. Despite widespread evidence promoting the benefits of 800 nm over 980 nm CW excitation in avoiding thermal heating in biological imaging, in contrary, we find that given the pulsed laser intensities appropriate for single particle imaging, at both 800 and 980 nm, that there is no significant local heating in air and in water. Finally, in order to confirm the applicability of infrared imaging at excitation intensities compatible with single nanoparticle tracking, DNA tightropes were exposed to pulsed infrared excitations at 800 and 980 nm. Our results show no appreciable change in the viability of DNA over time when exposed to either wavelengths. Our studies provide evidence for the feasibility of exploring protein-DNA interactions at the single molecule scale, using UCNPs as a reporter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6166686PMC
http://dx.doi.org/10.3389/fchem.2018.00416DOI Listing

Publication Analysis

Top Keywords

800 980
20
upconversion nanoparticles
8
thermal heating
8
pulsed excitation
8
excitation
7
infrared
5
0
5
1
5
optical temperature
4
temperature sensing
4

Similar Publications

Gastric emptying of five liquid meals which differ in their physicochemical properties have been measured in control dogs and dogs that have received a Heinecke-Mikulicz pyloroplasty alone, proximal gastric vagotomy without drainage, selective gastric vagotomy and pyloroplasty and truncal vagotomy and pyloroplasty. The first two phases of emptying have been computed by the method of least squares to obtain a logarithmic-linear pattern and are expressed as relative rates: The initial post-ingestion process is characterized by beta or the average relative rate of emptying in the first ten minutes, the basic or exponential rate as beta and the change in rate from the initial to basic pattern as deltabeta. Each measure of gastric emptying was statistically analyzed to determine specific differences in rates between the operations studied.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!