Validation of the Attitude Toward Living Liver Donation Questionnaire (PCID-DVH-Ríos) in Spanish-Speaking Populations: Characteristics and Psychometric Properties.

Transplant Proc

International Collaborative Donor Project, Murcia, Spain; Department of Surgery, Paediatrics, Obstetrics and Gynaecology, University of Murcia, Spain; Transplant Unit, Surgery Service, IMIB-Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain.

Published: October 2018

Introduction: Given the lack of a sufficient number of livers available for transplantation, living liver donation (LLD) is being developed in the Spanish-speaking world. Knowing the population's attitude toward this donation will help in designing more effective campaigns to increase the number of such donations. However, there are few validated questionnaires.

Objective: To analyze the psychometric characteristics of questionnaire PCID-DVH-Ríos [questionnaire of the International Collaborative Donor Project about Living Liver Donation ("Proyecto Colaborativo Internacional Donante sobre Donación de Vivo Hepático" in Spanish) developed by Dr. Ríos, in order to validate the questionnaire for the Spanish-speaking population.

Methods: The study population comprised native Spanish citizens. A sample of the population was obtained randomly and stratified by age and sex (N = 600) according to the following: 1. being older than 18 years; 2. being Spanish; and 3. living in Spain. Attitude was assessed using a validated questionnaire of attitude toward liver donation (PCID-DVH-Ríos). This questionnaire included items distributed into subscales or factors, an initial description of the data, an exploratory factor analysis, and an internal consistency analysis.

Results: The questionnaire consists of a total of 11 items, distributed into 3 subscales: 1. factor 1 (6 items); 2. factor 2 (3 items); and 3. factor 3 (2 items), presenting a total explained variance of 63.995%. The factors have an explained variance of F1: 38.461%; F2: 14.228%; and F3: 11.306%, respectively. The analysis of items and internal consistency supported the 3 factors' composition. The internal consistency of each factor is as follows: α1 = 0.80; α2 = 0.70; and α3 = 0.55, respectively.

Conclusions: The dimensions analyzed in the PCID-DVH-Ríos questionnaire on attitudes toward living liver donation show a good fit in relation to their factorial validity and internal consistency values.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.transproceed.2018.02.172DOI Listing

Publication Analysis

Top Keywords

liver donation
20
living liver
16
internal consistency
16
factor items
12
questionnaire pcid-dvh-ríos
8
pcid-dvh-ríos questionnaire
8
items distributed
8
distributed subscales
8
items factor
8
explained variance
8

Similar Publications

The Potential of Neonatal Organ Donation in Central Sweden.

Cell Transplant

January 2025

Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.

Pediatric organ transplant recipients have a higher risk for wait list mortality due to the scarcity of size matched organs. Neonatal organ donation could potentially ameliorate the discrepancy but is currently not implemented in Sweden. This study aims to evaluate the potential of neonatal organ donation in central Sweden using a standardized protocol with organ specific criteria.

View Article and Find Full Text PDF

: The rising use of liver grafts from donation after circulatory death (DCD) has been enabled by advances in normothermic regional perfusion (NRP) and machine perfusion (MP) technologies. We aimed to identify predictive biomarkers in DCD grafts subjected to NRP, followed by randomization to either normothermic machine perfusion (NMP) or dual hypothermic oxygenated perfusion (D-HOPE). : Among 57 DCD donors, 32 liver grafts were transplanted, and recipients were monitored for one week post-transplant.

View Article and Find Full Text PDF

Cost-effectiveness of Dual Hypothermic Oxygenated Machine Perfusion Versus Static Cold Storage in DCD Liver Transplantation.

Transplantation

February 2025

Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC Transplant Institute, University Medical Center Rotterdam, Rotterdam, the Netherlands.

Background: Ex situ machine perfusion of the donor liver, such as dual hypothermic oxygenated machine perfusion (DHOPE), is increasingly used in liver transplantation. Although DHOPE reduces ischemia/reperfusion-related complications after liver transplantation, data on cost-effectiveness are lacking. Our objective was to evaluate the cost-effectiveness of DHOPE in donation after circulatory death (DCD) liver transplantation.

View Article and Find Full Text PDF

Unlocking Rural Live-Kidney Donation Through Insights From a Decade-Long Analysis at a Single Center in the Northern Great Plains.

Transplant Proc

January 2025

Avera McKennan Hospital and University Health Center, Avera Medical Group Transplant & Liver Surgery, Sioux Falls, South Dakota; Department of Surgery, University of South Dakota, Sanford School of Medicine, Sioux Falls, South Dakota; Department of Internal Medicine, University of South Dakota, Sanford School of Medicine, Sioux Falls, South Dakota. Electronic address:

Background: Data on barriers to live-kidney donation in the rural United States is limited despite its widespread adoption across the country.

Methods: A retrospective review of 1776 self-referrals for live-kidney donation between June 1, 2012, and May 31, 2022, was conducted. Multivariate analyses evaluated independent factors which may have potentially influenced donation at different stages in its process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!