A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic Value of Energy Dispersive Hand-Held X-ray Fluorescence Spectrometry in Determining Trace Element Concentrations in Ovine Liver. | LitMetric

Diagnostic Value of Energy Dispersive Hand-Held X-ray Fluorescence Spectrometry in Determining Trace Element Concentrations in Ovine Liver.

Biol Trace Elem Res

Department of Paraclinical Sciences, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, South Africa.

Published: August 2019

There are no data available on the use of hand-held X-ray fluorescence (XRF) spectrometry to determine trace element concentrations in veterinary diagnostics. The hand-held XRF spectrometer is easy to use and does not require extensive training for the operator. In Sub-Saharan Africa with few centralised analytical laboratories equipped with expensive apparatus or mass spectrometry capabilities, trace element analysis using the hand-held XRF spectrometer provides an alternative. The objective of this study was to compare ovine hepatic copper (Cu), iron (Fe), manganese (Mn), molybdenum (Mo), selenium (Se) and zinc (Zn) concentrations as obtained with the hand-held XRF spectrometer to those of a reference laboratory using inductively coupled plasma mass spectrometry (ICP-MS). Thirty ovine livers were obtained from an abattoir; prepared as wet blended and oven-dried samples and analysed. Bayesian correlation was used to assess the correspondence between results from the XRF and ICP-MS analyses. The oven-dried preparation procedure for XRF provided the best correlation with the ICP-MS data. The correlations for Cu and Zn were strong and the XRF method may represent a suitable substitute for ICP-MS analysis. For Mn and Fe the correlations were moderately strong and the XRF method may be suitable. For Mo, the correlation was weak and XRF cannot be recommended. Selenium could not be detected in samples prepared by either method. Hand-held XRF spectrometry was a practical method to determine liver concentrations of specific trace elements under African conditions and may significantly reduce the turn-around time of analysis, but unfortunately the apparatus is expensive.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12011-018-1546-0DOI Listing

Publication Analysis

Top Keywords

hand-held xrf
16
trace element
12
xrf spectrometer
12
xrf
10
hand-held x-ray
8
x-ray fluorescence
8
element concentrations
8
xrf spectrometry
8
mass spectrometry
8
strong xrf
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!