Background And Purpose: The accuracy of DSC-MR imaging CBV maps in glioblastoma depends on acquisition and analysis protocols. Multisite protocol heterogeneity has challenged standardization initiatives due to the difficulties of in vivo validation. This study sought to compare the accuracy of routinely used protocols using a digital reference object.

Materials And Methods: The digital reference object consisted of approximately 10,000 simulated voxels recapitulating typical signal heterogeneity encountered in vivo. The influence of acquisition and postprocessing methods on CBV reliability was evaluated across 6912 parameter combinations, including contrast agent dosing schemes, pulse sequence parameters, field strengths, and postprocessing methods. Accuracy and precision were assessed using the concordance correlation coefficient and coefficient of variation.

Results: Across all parameter space, the optimal protocol included full-dose contrast agent preload and bolus, intermediate (60°) flip angle, 30-ms TE, and postprocessing with a leakage-correction algorithm (concordance correlation coefficient = 0.97, coefficient of variation = 6.6%). Protocols with no preload or fractional dose preload and bolus using these acquisition parameters were generally less robust. However, a protocol with no preload, full-dose bolus, and low (30°) flip angle performed very well (concordance correlation coefficient = 0.93, coefficient of variation = 8.7% at 1.5T and concordance correlation coefficient = 0.92, coefficient of variation = 8.2% at 3T).

Conclusions: Schemes with full-dose preload and bolus maximize CBV accuracy and reduce variability, which could enable smaller sample sizes and more reliable detection of CBV changes in clinical trials. When a lower total contrast agent dose is desired, use of a low flip angle, no preload, and full-dose bolus protocol may provide an attractive alternative.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6239921PMC
http://dx.doi.org/10.3174/ajnr.A5827DOI Listing

Publication Analysis

Top Keywords

concordance correlation
16
correlation coefficient
16
digital reference
12
contrast agent
12
preload bolus
12
flip angle
12
coefficient variation
12
acquisition analysis
8
reference object
8
postprocessing methods
8

Similar Publications

Background: Electrographic flow (EGF) mapping allows for the visualization of global atrial wavefront propagations. One mechanism of initiation and maintenance of atrial fibrillation (AF) is stimulation from EGF-identified focal sources that serve as driver sites of fibrillatory conduction. Electrographic flow consistency (EGFC) further quantifies the concordance of observed wavefront patterns, indicating that a healthier substrate shows more organized wavefront propagation and higher EGFC.

View Article and Find Full Text PDF

Background: Wilms tumor is one of the most common pediatric kidney cancers with poor prognosis. This study aims to explore the predictive values of lymph nodes (LNs), positive lymph node density (LND) and log odds of positive lymph nodes (LODDS) for the 5-year mortality of children with Wilms tumor.

Methods: The cohort study collected the data of 874 participants with Wilms tumor in the Surveillance, Epidemiology, and End Results (SEER) database.

View Article and Find Full Text PDF

Airway Mycobiota-Microbiota During Pulmonary Exacerbation of Cystic Fibrosis Patients: A Culture and Targeted Sequencing Study.

Mycoses

January 2025

Unité de Parasitologie-Mycologie, Département de Prévention, Diagnostic et Traitement Des Infections, CHU Henri Mondor, Assistance Publique Des Hôpitaux de Paris (APHP), Creteil, France.

Background: The airways of patients with cystic fibrosis (pwCF) harbour complex fungal and bacterial microbiota involved in pulmonary exacerbations (PEx) and requiring antimicrobial treatment. Descriptive studies analysing bacterial and fungal microbiota concomitantly are scarce, especially using both culture and high-throughput-sequencing (HTS).

Objectives: We analysed bacterial-fungal microbiota and inter-kingdom correlations in two French CF centres according to clinical parameters and antimicrobial choices.

View Article and Find Full Text PDF

In hemodialysis patients, blood pressure (BP) measured at the postdialysis period (POSBP) can be used to diagnose hypertension. However, the optimal time point for POSBP remains uncertain. This cross-sectional study evaluated 210 long-term dialysis patients (66.

View Article and Find Full Text PDF

Gated equilibrium radionuclide angiography (ERNA), or multigated acquisition scanning, is a well-established technique to monitor left ventricular ejection fraction (LVEF) in patients treated with potentially cardiotoxic chemotherapy. To determine the results of a true change in LVEF, low inter- and intrareader variability is important. The aim of this study was to investigate inter- and intrareader variability in LVEF measurements using 2 different commercially available software packages with cardiac MR (CMR) as a reference standard.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!