Clinical outcomes of partial and full-arch all-ceramic implant-supported fixed dental prostheses. A systematic review and meta-analysis.

Clin Oral Implants Res

Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Berlin, Germany.

Published: October 2018

Objective: To assess the survival and technical complication rate of partial and full-arch all-ceramic implant-supported fixed dental prostheses (P-FDP/FA-FDP) and supporting implants.

Materials And Methods: An electronic search through three databases (MEDLINE/Pubmed, Cochrane Library, Embase) was conducted to identify relevant clinical studies with an observation period of at least 12 months, including ≥15 patients. Reconstruction and implant survival rates, technical complications and confounding variables such as processed/installed materials, retention mode and location in the mouth were obtained. Failure and complication rates were analyzed using standard Poisson regression models to calculate 5-year survival and complication estimates.

Results: A total of five studies for the P-FDP group and seven studies for the FA-FDP group were included, throughout evaluating veneered zirconia reconstructions. In the P-FDP group, reconstructions were located in posterior regions. Meta-analysis indicated survival estimates on the reconstruction level of 98.3% and 97.7% for P- and FA-FDPs after 5 years. However, chipping of the veneering ceramic was frequent, resulting in estimated 5-year complication rates of 22.8% (P-FDPs) and 34.8% (FA-FDPs). Five-year survival estimates of implants supporting P-FDPs and FA-FDPs of 98.5% and 99.4% were calculated, respectively. Including a total of 540 FDPs, one screw-loosening and 11 de-cementations were reported. Confounding variables were not found to have a significant influence on survival and complication rates.

Conclusions: All-ceramic implant-supported P- and FA-FDPs comprising veneered zirconia frameworks showed high survival but clinically inacceptable fracture rates of the veneering ceramic. Their suitability with regard to this indication and a successful long-term outcome needs to be further evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.13345DOI Listing

Publication Analysis

Top Keywords

all-ceramic implant-supported
12
partial full-arch
8
full-arch all-ceramic
8
implant-supported fixed
8
fixed dental
8
dental prostheses
8
confounding variables
8
complication rates
8
survival complication
8
p-fdp group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!