A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mechanical Dilation With a Nylon Monofilament for 0.1-mm Anastomoses. | LitMetric

Mechanical Dilation With a Nylon Monofilament for 0.1-mm Anastomoses.

Ann Plast Surg

Department of Plastic and Reconstructive Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.

Published: February 2019

Despite advances in supermicrosurgical techniques, the ability to anastomose vessels with a diameter of less than 0.2 mm remains limited. One of the reasons for this limitation is that the dilation methods currently available, such as inserting the tip of a microforceps into the lumen or topical application of a vasodilator such as papaverine hydrochloride or xylocaine spray, are not effective in very small vessels. To overcome this problem, we have developed a method whereby nylon monofilaments are placed inside the vessel lumen to act as a dilator. Using this method, a smaller nylon monofilament is inserted into the vessel as a guide before inserting a larger nylon monofilament as a dilator. After the smaller guide monofilament has been inserted, it is then much easier to insert another monofilament for dilation, even if it is a larger one. Using this method, even a vessel with a diameter of less than 0.1 mm could be dilated to greater than 0.2 mm. The dilator monofilament can also be used as an intravascular stent in the anastomosis. We have found that anastomosis of vessels with a diameter of less than 0.1 mm is possible using this method. In our experience, the immediate patency rate has been 100%. We believe mechanical dilation with a nylon monofilament is helpful for supermicrosurgery and even ultramicrosurgery.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SAP.0000000000001632DOI Listing

Publication Analysis

Top Keywords

nylon monofilament
16
mechanical dilation
8
dilation nylon
8
vessels diameter
8
monofilament inserted
8
monofilament
7
nylon
5
monofilament 01-mm
4
01-mm anastomoses
4
anastomoses despite
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!