Purpose: In recent years (2011-2016), men's 800-m championship running performances have required greater speed than previous eras (2000-2009). The "anaerobic speed reserve" (ASR) may be a key differentiator of this performance, but profiles of elite 800-m runners and their relationship to performance time have yet to be determined.

Methods: The ASR-determined as the difference between maximal sprint speed (MSS) and predicted maximal aerobic speed (MAS)-of 19 elite 800- and 1500-m runners was assessed using 50-m sprint and 1500-m race performance times. Profiles of 3 athlete subgroups were examined using cluster analysis and the speed reserve ratio (SRR), defined as MSS/MAS.

Results: For the same MAS, MSS and ASR showed very large negative (both r = -.74 ± .30, ±90% confidence limits; very likely) relationships with 800-m performance time. In contrast, for the same MSS, ASR and MAS had small negative relationships (both r = -.16 ± .54; possibly) with 800-m performance. ASR, 800-m personal best, and SRR best defined the 3 subgroups along a continuum of 800-m runners, with SRR values as follows: 400-800 m ≥ 1.58, 800 m ≤ 1.57 to ≥ 1.48, and 800-1500 m ≤ 1.47 to ≥ 1.36.

Conclusion: MSS had the strongest relationship with 800-m performance, whereby for the same MSS, MAS and ASR showed only small relationships to differences in 800-m time. Furthermore, the findings support the coaching observation of three 800-m subgroups, with the SRR potentially representing a useful and practical tool for identifying an athlete's 800-m profile. Future investigations should consider the SRR framework and its application for individualized training approaches in this event.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijspp.2018-0163DOI Listing

Publication Analysis

Top Keywords

800-m performance
12
800-m
11
speed reserve
8
800-m runners
8
performance time
8
mss asr
8
performance
6
speed
5
asr
5
mss
5

Similar Publications

This study investigated sex differences in the development of pulmonary edema and exercise-induced arterial hypoxemia (EIAH) in well-trained endurance athletes during near-maximal exercise in a real-world setting. Twenty participants (10M vs. 10F; V̇Opeak: 69.

View Article and Find Full Text PDF

The present study demonstrates the significance of the C/N ratio and double helical ribbon (DHR) impeller in the anaerobic co-digestion (AnCo-D) of sugar refining process (SRP) effluent and molasses-based distillery spent wash (DSW) for improved biogas production. Both SRP & DSW were mixed in different percentages to achieve an optimum C/N ratio. Further biomethane potential analysis of mixed feeds with different C/N ratios was performed.

View Article and Find Full Text PDF

Common salt (NaCl) causes developmental, behavioral, and physiological defects in .

Nutr Neurosci

January 2025

Neural Developmental Biology Lab, Department of Life Science, NIT Rourkela, Rourkela, Odisha, India.

Article Synopsis
  • The study investigates the toxicity of salt on obesity using Drosophila larvae and adult flies, testing varying salt concentrations (50-800 µM).
  • At lower concentrations (50 and 200 µM), significant weight gain and increased feeding behavior were observed, with larvae and adult flies displaying abnormal responses to temperature and light stimuli.
  • The findings reveal that while lower salt concentrations induce stronger adverse effects, higher concentrations deter feeding, suggesting a complex relationship between salt intake and obesity-related behaviors.
View Article and Find Full Text PDF

An Optoelectronic Sensing Real-Time Glucose Detection Film Using Photonic Crystal Enhanced Rare Earth Fluorescence and Additive Manufacturing.

Small

January 2025

State Key Laboratory of Electromechanical Integrated Manufacturing of High-performance Electronic Equipment, School of Mechano-Electronic Engineering, School of Life Science and Technology, Xidian University, Xi'an, Shaanxi, 710071, China.

In this research, a novel detection method employing rare-earth upconversion nanoparticle (UCNP) as the core, coated with MnO nanosheets is designed, which formed a color and fluorescence dual-responsive UCNP composite material, MnO-modified NaYF:Yb,Tm@NaYF. By enabling both colorimetric and fluorescence methods simultaneously, this composite material allows for the detection of glucose concentration under different conditions, while exhibiting strong resistance to environmental interference, chemical stability, and accuracy. To further enhance the sensitivity of the detection method, a photonic crystals (PCs)-PDMS array where polymethyl methacrylate PCs are deposited onto a substrate composed of PDMS-glass slice with hydrophobic surfaces is developed.

View Article and Find Full Text PDF

The application of the Internet combined with extracurricular running exercise plays an important role in promoting the reform of school physical education teaching and the healthy development of students' physical fitness. 2379 students of Guilin Medical College used the Flash Campus APP for 30 weeks of running exercise during the school period, and the Wilcoxon test and t-test were used to statistically test the data of 50 m, standing long jump, lung capacity, seated forward bending, height, and body weight; men's pull-ups, 1,000 m; and women's sit-ups, 800 m pre- and post-tests. The Z/t values of men's 50 m, standing long jump, pull-ups, and lung capacity; women's 50 m running, standing long jump, sit-ups, lung capacity, and sitting prone flexion after extracurricular running exercise were - 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!