This paper presents the synthesis of highly biocompatible and biodegradable poly(lactide- co-glycolide) (PLGA) microchamber arrays sensitive to low-intensity therapeutic ultrasound (1 MHz, 1-2 W, 1 min). A reliable method was elaborated that allowed the microchambers to be uniformly filled with epinephrine hydrochloride (EH), with the possibility of varying the cargo amount. The maximum load of EH was 4.5 μg per array of 5 mm × 5 mm (about 24 pg of EH per single microchamber). A gradual, spontaneous drug release was observed to start on the first day, which is especially important in the treatment of acute patients. Ultrasound triggered a sudden substantial release of EH from the films. In vivo real-time studies using a laser speckle contrast imaging system demonstrated changes in the hemodynamic parameters as a consequence of EH release under ultrasound exposure. We recorded a decrease in blood flow as a vascular response to EH release from a PLGA microchamber array implanted subcutaneously in a mouse. This response was immediate and delayed (1 and 2 days after the implantation of the array). The PLGA microchamber array is a new, promising drug depot implantable system that is sensitive to external stimuli.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.8b15109DOI Listing

Publication Analysis

Top Keywords

plga microchamber
16
microchamber array
12
epinephrine hydrochloride
8
microchamber
5
array
5
controlled release
4
release epinephrine
4
plga
4
hydrochloride plga
4
array vivo
4

Similar Publications

Expandable metallic stent placement is often the only way to treat airway obstructions. Such treatment with an uncoated stent causes granulation proliferation and subsequent restenosis, resulting in the procedure's adverse complications. Systemic administration of steroids drugs in high dosages slows down granulation tissue overgrowth but leads to long-term side effects.

View Article and Find Full Text PDF

This paper presents the synthesis of highly biocompatible and biodegradable poly(lactide- co-glycolide) (PLGA) microchamber arrays sensitive to low-intensity therapeutic ultrasound (1 MHz, 1-2 W, 1 min). A reliable method was elaborated that allowed the microchambers to be uniformly filled with epinephrine hydrochloride (EH), with the possibility of varying the cargo amount. The maximum load of EH was 4.

View Article and Find Full Text PDF

In vitro and in vivo activities of leukotriene B4-loaded biodegradable microspheres.

Prostaglandins Other Lipid Mediat

February 2007

Departamento de Análises Clínicas, Toxicológicas e Bromatológicas, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, Av. do Café s/n, 14040-903 Ribeirão Preto, Brazil.

Leukotriene B(4) (LTB(4)) is a potent inflammatory mediator and stimulates the immune response. In addition, LTB(4) promotes leukocyte functions such as phagocytosis, chemotaxis and chemokinesis of polymorphonuclear leukocytes, as well as modulates cytokine release. However, some physicochemical characteristics of leukotrienes, such as poor solubility in water and chemical instability, make them difficult to administer in vivo.

View Article and Find Full Text PDF