Lead: a hidden "untested" risk in neonatal blood transfusion.

Pediatr Res

Pediatrics and Neonatology Department, Faculty of Medicine, Suez Canal University, Ismailia, Egypt.

Published: January 2019

AI Article Synopsis

Article Abstract

Background: Neonates may be exposed to lead (Pb) through blood transfusions from donors. Pb exposure has neurological, cardiovascular, renal, and other adverse effects. The study aimed to (i) determine the blood lead levels (BLLs) in different blood product units (whole blood, packed red blood cells (pRBCs), platelets, and plasma transfused to neonates) and (ii) estimate the proportion of units with high BLLs.

Methods: Residual blood from blood bank bags that were used for neonatal transfusion were collected: 25 samples from each type of blood product except for whole blood (10 samples). The Pb analysis was performed using the atomic absorption method. The study was conducted at the Suez Canal University Hospital, Egypt.

Results: The mean of BLL in pRBCs, platelets, plasma, and whole blood were 136, 199, 108, and 130 µg/L, respectively; 60% contained Pb above 50 µg/L. The highest BLLs were in platelet units.

Conclusions: The present study showed for the first time that platelets and plasma in addition to whole blood and pRBCs used for neonatal transfusions are sources of Pb. Re-evaluation of the guidelines is mandatory for the safety of the neonates. Long-term neurodevelopment assessment of neonates exposed to high Pb is warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41390-018-0175-9DOI Listing

Publication Analysis

Top Keywords

blood
12
platelets plasma
12
neonates exposed
8
blood product
8
prbcs platelets
8
lead hidden
4
hidden "untested"
4
"untested" risk
4
risk neonatal
4
neonatal blood
4

Similar Publications

l-theanine: From tea leaf to trending supplement - does the science match the hype for brain health and relaxation?

Nutr Res

January 2025

Department of Molecular Medicine, University of Padova, Padova, Italy; IMDEA-Food, Madrid, Spain. Electronic address:

l-Theanine is a unique non-protein amino acid found abundantly in tea leaves. Interest in its potential use as a dietary supplement has surged recently, especially claims related to promoting relaxation and cognitive enhancement. This review surveys the chemistry, metabolism, and purported biological activities of l-theanine.

View Article and Find Full Text PDF

Background: Type 1 diabetes is the most common endocrine health condition among youth. Healthcare professionals must consider evidence-based guidelines in managing children and adolescents with diabetic ketoacidosis (DKA). The current study aims to assess the outcomes of implementing clinical guidelines by the American Diabetes Association to manage DKA among pediatrics in an emergency department in Palestine.

View Article and Find Full Text PDF

Mycobacterium tuberculosis (M.tb) infection can lead to various outcomes, including active tuberculosis or latent tuberculosis infection (LTBI). Household contacts of TB cases have a high risk of acquiring LTBI.

View Article and Find Full Text PDF

Background: Segmentation models for clinical data experience severe performance degradation when trained on a single client from one domain and distributed to other clients from different domain. Federated Learning (FL) provides a solution by enabling multi-party collaborative learning without compromising the confidentiality of clients' private data.

Methods: In this paper, we propose a cross-domain FL method for Weakly Supervised Semantic Segmentation (FL-W3S) of white blood cells in microscopic images.

View Article and Find Full Text PDF

External delay and dispersion correction of automatically sampled arterial blood with dual flow rates.

Biomed Phys Eng Express

January 2025

Brain Health Imaging Centre, Centre for Addiction and Mental Health, B68-250 College St, Toronto, Ontario, M5T 1R8, CANADA.

Objective: Arterial sampling for PET imaging often involves continuously measuring the radiotracer activity concentration in blood using an automatic blood sampling system (ABSS). We proposed and validated an external delay and dispersion correction procedure needed when a change in flow rate occurs during data acquisition. We also measured the external dispersion constant of [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!